4. High Limit Safety Switch
A limit switch has been installed on the IB75. This switch automatically turns off the appliance if it becomes too hot. If
this happens, do not attempt to operate the appliance until it has been examined by a qualified service technician.
The high limit switch is located in the center of the appliance and directly in front of the smoke shield. See Figure 23.
5. Glass Breakage/Cleaning
It is recommended to wear gloves while handling or removing glass.
Clean glass after initial 4-6 hours burning time. This is to remove any film that develops from oils and log burn.
After initial cleaning, clean as needed.
Handle glass panel with care to avoid striking or scratching it on hard objects.
To clean the glass, use a nonabrasive, mild cleaning solution (i.e. Brasso). Apply an adequate amount to the
glass and wipe off per manufacturer’s instructions. Contact your local stove shop or fireplace accessories store
for further recommendations.
In the event of glass breakage, carefully remove the glass frame. This will allow the removal of all glass fragments
and sheet metal edge protection strips. Vacuum all remaining glass pieces with a shop vac.
ordered through your local distributor/dealer. Never use substitute material. Only fully tempered soda lime safety
glass may be used on this appliance.
Note:
and children a safe distance away.
18
Replace glass doors only with a Hearth & Home Technologies glass door assembly
When cleaning the glass, NEVER use abrasive materials. NEVER clean glass when it is hot. Keep pets
35048 Rev L