▼ Exit ILOM

To end an ILOM session, at the CLI prompt, type exit.
If you are logged in to the CMM, you must exit the ILOM session on the server
module first, and then type exit again to end the ILOM session on the CMM.
Applying Main Power to the Server
Module
To install an operating system or to fully operate the server module, you must apply
main power to the server module host.
This section includes the following topics:
"Apply Main Power to Server SP and Host" on page 26
"Power Off From Main Power" on page 27
"Troubleshoot Server Power States" on page 27

▼ Apply Main Power to Server SP and Host

1. Verify that the OK/Power LED on the front panel of the server module is in the
standby power mode.
In standby power state, the OK/Power LED on the front panel of the server
module illuminates a standby blink (0.1 second on, 2.9 seconds off).
Note – The server power state will not be set to standby if the CMM in the chassis
is not present or accessible to the server SP. The OK/Power LED on the server will
remain off. In this situation, you should proceed by powering on the server as
instructed below.
2. Press and release the recessed Power button on the server module front panel.
The OK/Power LED transitions from standby blink to slow blink while the host
OS boots. When the host OS is booted, the LED transitions to a steady-on state.
26
Sun Blade X6270 M2 Server Module Installation Guide • October 2010