You are now ready to hook up the Insert to gas supply. Be sure gas plumbing instructions and all state and local
codes have been carefully followed. Be sure all items on Installation Check-Off List have been completed.
NOTE: AGA APPROVED FLEX LINES ARE APPROVED FOR USE WITH MENDOTA INSERTS.
19.
Carefully slide the Insert into place in the fireplace opening. At this time, check that Insert is level and plumb with
the fireplace opening and positioned in the middle of the opening. If Insert is unsteady or needs leveling, the unit
may need to be "shimmed with washers under the bottom corners of insert.
20. The proper Insert Faceplate can now be placed in position. Assemble surround by following instructions supplied
with faceplate kit. Select the appropriate size of faceplate to cover the area between the Insert and existing fireplace
opening.
INSTALLATION, SERVICING AND REPAIR MUST BE DONE BY A QUALIFIED SERVICE PERSON. THE INSERT SHOULD BE
INSPECTED AT LEAST ANNUALLY BY A PROFESSIONAL SERVICE PERSON. MORE FREQUENT CLEANING MAY BE
REQUIRED DUE TO EXCESSIVE LINT FROM CARPETING, BEDDING MATERIAL, ETC. IT IS IMPERATIVE THAT THE
CONTROL COMPARTMENT BURNERS AND CIRCULATING AIR PASSAGEWAYS OF THE INSERT BE KEPT CLEAN.
NOTE: FOR EVERY 1" THAT THE UNIT IS
RAISED ABOVE THE ROOM FLOOR LEVEL, THE
NON-COMBUSTIBLE PROTECTION MAY BE
REDUCED BY 2".
NOTE: IF UNIT IS ELEVATED 6" OR MORE
ABOVE ROOM FLOOR LEVEL, NO PROTECTIVE
SURFACE IS REQUIRED AT FLOOR LEVEL.
In most installations, a 16" non-combustible protector is required in front of the unit's glass door
surface on the floor or raised hearth. This protection can be any non-combustible material such
as 24-gauge sheet metal, tile, brick, concrete board, etc. Please note that the required 16" clear-
ance starts at the front face of the glass door. If replacing a wood-burning insert with this gas in-

RAISED HEARTH SPECIFICATIONS

NON COMBUSTIBLE
SURFACE REQUIRED
16"
NON-COMBUSTIBLE REQUIRED
ELEVATED HEARTH
IMPORTANT
ZC or MASONRY FIREBOX
BOTTOM STRUCTURE
15