Raised Hearth Specifications - Mendota FV44i Installation & Operating Instructions Manual

Full view direct vent gas fireplace insert with premium texture fiber logs combustion system
Table of Contents

Advertisement

18.
You are now ready to hook up the Insert to gas supply. Be sure gas plumbing instructions and all state and local
codes have been carefully followed. Be sure all items on Installation Check-Off List have been completed.
NOTE: AGA APPROVED FLEX LINES ARE APPROVED FOR USE WITH MENDOTA INSERTS.
19.
Carefully slide the Insert into place in the fireplace opening. At this time, check that Insert is level and plumb with
the fireplace opening and positioned in the middle of the opening. If Insert is unsteady or needs leveling, the unit
may need to be "shimmed with washers under the bottom corners of insert.
20. The proper Insert Faceplate can now be placed in position. Assemble surround by following instructions supplied
with faceplate kit. Select the appropriate size of faceplate to cover the area between the Insert and existing fireplace
opening.
INSTALLATION, SERVICING AND REPAIR MUST BE DONE BY A QUALIFIED SERVICE PERSON. THE INSERT SHOULD BE
INSPECTED AT LEAST ANNUALLY BY A PROFESSIONAL SERVICE PERSON. MORE FREQUENT CLEANING MAY BE
REQUIRED DUE TO EXCESSIVE LINT FROM CARPETING, BEDDING MATERIAL, ETC. IT IS IMPERATIVE THAT THE
CONTROL COMPARTMENT BURNERS AND CIRCULATING AIR PASSAGEWAYS OF THE INSERT BE KEPT CLEAN.
In most installations, a 16" non-combustible protector is required in front of the unit's glass door
surface on the floor or raised hearth. This protection can be any non-combustible material such
...IMPORTANT...

RAISED HEARTH SPECIFICATIONS

11
BOTTOM EDGE OF
GLASS WINDOW