ERROR CODE
DELUXE
TRACTION MOTOR
50
PROBLEM
LOW BATTERY VOLTAGE
TRACTION MOTOR
DISCONNECTED
SHORT
CIRCUIT
AUX FAULT or
ACTUATOR (DECK or SQUE)
OVERCURRENT
VACUUM MOTOR TRIP
BRUSH MOTOR TRIP
THROTTLE TRIP ERROR
CONTROL SYSTEM TRIP
SOLENOID BRAKE
HIGH BATTERY VOLTAGE
86372820 Chariot 3 iExtract 26 Duo
SOLUTION
THE BATTERY NEEDS CHARGING OR THERE IS A BAD
CONNECTION TO THE BATTERY
THE TRACTION MOTOR HAS A BAD CONNECTION, CHECK
CONNECTIONS TO MOTOR
THE TRACTION MOTOR HAS A SHORT CIRCUIT TO THE
CHECK AUX OUTPUT DEVICES, CHECK ALL ASSOCIATED
WIRING TO AUX DEVICES
THE VACUUM MOTOR HAS EXCESSIVE CURRENT. CHECK
FOR SHOR CIRCUITS OR OTHER DAMAGE.
THE BRUSH MOTOR HAS EXCESSIVE CURRENT, CHECK
FOR SHORT CIRCUITS, PADS OR OTHER DAMAGE.
THE THROTTLE IS DEFLECTED OR ASSOCIATED WIRING
HAS A BREAK OR SHORT CIRCUIT
THE CONTROL SYSTEM IS IN ERROR, CHECK ALL
CONNECTIONS TO CONTROLLER
THE SOLENOID HAS A BAD CONNECTION, CHECK
CONNECTION TO BRAKE
EXCESSIVE BATTERY VOLTAGE, CHECK FOR POOR
BATTERY CONDITION
BATTERY