Battery Charger Programming - Windsor iExtract 26 Duo Operating Instructions Manual

Table of Contents

Advertisement

Onboard Charger (Optional)
Circuit breaker must be off before unplugging
batteries.
Le disjoncteur doit être éteint avant de débrancher
les batteries

Battery Charger Programming

For machines equipped with optional on-board charger.
When replacing batteries, charger programming
changes may be required. If replacing batteries with
same type, (e.g. maintenance free batteries with main-
tenance free) no programming is required. When
batteries with different type (e.g.maintenance free with
wet cell), programming change are required. Failure to
make programming changes may lead to reduced
battery life.
1. Remove four screws from charger mounting
bracket. Lift charger out of console.
2. Peel back label on charger to access dip switches.
3. Change switches to correct battery type.
86372820 Chariot 3 iExtract 26 Duo
DIP DIP DIP
1
2
OFF ON ON
LEAD ACID
ON OFF OFF
DISCOVER AGM
4. Replace charger label and lower charger back into
console. Tighten four screws to secure mounting
bracket to console.
Maintenance
DIP
DIP DIP DIP DIP
3
4
5
6
7
8
ON
OFF ON ON OFF
OFF
OFF ON ON OFF