Operations
Battery Charger Fault Codes
Fault
No Display
No display on charger, no LED indicators.
Incorrect battery connection or no battery
bat
connection
The maximum voltage admissible by the battery
E01
has been exceeded. The charge cycle was
interrupted.
The maximum voltage admissible by the battery
E02
has been exceeded. The charge cycle was
interrupted.
The maximum time for the charging phase has
E03
been exceeded. The charge cycle was inter-
rupted.
The total safety time has interrupted the charge
Sct
cycle.
Srt
Internal charger fault.
22
Description
86408910 Lightning BDP 50-2000 W
Remedy
Check that plug is connected to an operating
wall outlet. Check 20A fuse.
Check the connection and the polarity of the
battery connection.
Restart the charge cycle. If problem persists,
battery pack may be damaged.
Restart the charge cycle. If problem persists,
battery pack may be damaged.
Restart the charge cycle. If problem persists,
battery pack may be damaged.
Restart the charge cycle. If problem persists,
battery pack may be damaged.
Replace battery charger.