5 Configuration
Leaving water temperature: Emitter type
#
Code
[A.3.1.1.7]
[90B]
Reaction time of the system:
▪ 0: Quick. Example: Small water
volume and fan coils.
▪ 1: Slow. Example: Large water
volume, floor heating loops.
Depending on the system water volume
and the heat emitters type, the heat up
or cool down of a space can take
longer. This setting can compensate for
a slow or a quick heating/cooling
system by adjusting the unit capacity
during the heat up/cool down cycle.
Quick heat up function
#
Code
N/A
[C0A]
Indoor quick heat up function:
▪ 0: OFF.
▪ 1 (default): On.
Only applicable in case of room
thermostat control. The function will
start up the gas boiler when the actual
room temperature is 3°C lower than the
desired room temperature. The large
boiler capacity can quickly boost up the
room temperature to the desired
temperature. This can be useful after
long periods of absence or after a
breakdown of the system.
Domestic hot water control
Only applicable in case an optional domestic hot water tank is
installed.
#
Code
[A.4.1]
[60D]
Domestic hot water Type:
▪ 0 (Reheat only): Only reheat operation
is allowed.
▪ 1 (Reheat + sched.): Same as 2, but
between the scheduled heatup cycles,
reheat operation is allowed.
▪ 2 (Scheduled only): The domestic hot
water tank can ONLY be heated
according to a schedule.
[A.4.3.1]
N/A
How is the tank temperature to be
displayed on the user interface?
▪ As temperature.
60°C
▪ As graphic: The temperature has to be
displayed as available hot water for
x persons. If you choose this, you also
have to configure which number
equals which temperature under
[A.4.3.2.1]~[A.4.3.2.6]:
4
[A.4.5]
[60E]
The maximum temperature that users
can select for the domestic hot water.
You can use this setting to limit the
temperature at the hot water taps.
Installation manual
16
Description
Description
Description
Contact/helpdesk number
#
Code
[6.3.2]
N/A
Number that users can call in case of
problems.
Daikin Altherma hybrid heat pump – heat pump module
Description
EHYHBH05AAV3 + EHYHBH/X08AAV3
4P3495871C – 2013.10