10 Technical specifications
EN
Fan-and-filter unit,
RAL 7035
EMC fan-and-filter
unit,
RAL 7035
Rated operating
voltage
Rated current max.
Power
consumption
Pre-fuse T
Dimensions
B1/H1
B2/H2
T1
T2
(max. installation
depth)
Air throughput,
unimpeded air flow
Air throughput with
outlet filter
including standard
filter mat
Outlet filter
EMC
outlet filter
Fan
Noise pressure
level
Operating
temperature
Storage
temperature
Protection category
(to EN 60 529)
Tab. 4: Technical specifications
14
Unit
–
3240.100
3240.110
–
3240.600
–
V
230, 1~,
115, 1~,
Hz
50/60
50/60
A
0.19/0.18
0.38/0.36
W
33/33
A
2
4
mm
255 x 255
mm
224 x 224
mm
25
mm
107
m³/h
180/160
1 x 3240.200: 138/121
m³/h
2 x 3240.200: 165/140
1 x 3243.200: 165/140
–
3240.200
–
3240.060
Diagonal, self-starting
–
shaded pole motor
dB (A) 51/46
°C
–30 to +55
°C
–30 to +70
IP 54 standard
–
IP 55 with additional fine filter mat or hose-proof hood
IP 56 with hose-proof hood
Rittal fan-and-filter unit assembly and operating instructions
Model No. SK
3240.124
3241.100
–
3241.600
230, 1~,
24 (DC)
50/60
0.07
0.27/0.28
10
42/46
2
4
180
230/250
1 x 3240.200: 183/205
2 x 3240.200: 203/230
1 x 3243.200: 203/230
Diagonal,
Diagonal, self-starting
DC motor
shaded pole motor
51
54/56
We reserve the right to make technical modifications.
3241.110
3241.124
–
–
115, 1~,
24 (DC)
50/60
0.54/0.52
0.2
43/46
25
2
230
Diagonal,
DC motor
54