Wiring the Exhaust Blower

Do not connect 110-120 VAC to the gas control valve or wiring system of this fireplace.
The exhaust box is wired to the 120v line exiting the exhaust blower rheostat. Connect a minimum
12 gauge sheathed three-wire electrical line from the rheostat to the exhaust blower junction box.
Attach the wires as shown below.
Fireplace Junction Box
Black
White
Green
Molex (installed
in fireplace)
Remove the cover plate on the exhaust blower
housing.
Route the electrical line through the romex
connector and attach the 120v wiring as detailed in
the wiring diagram.
© Travis Industries
Installation
Black
Black
White
Green
Romex
Clamp
Rheostat Junction Box
(for qualified installers only)
Rheostat
White
Black
White
Green
4091229
Capacitor
Black
Black
Black
White
Green
Exhaust Blower Junction Box
100-01246_000
21