6.13 Check code Trouble shooting CH23, CH28
Display
Title
code
DC Link
23
Low voltage.
DC Link
28
High voltage
Check Flow Chart
Check the wire
connection.(U,V,W)
Is it normal ?
Yes
Is it normal ?
Yes
Is it normal ?
Yes
Check the input power
Copyright ©2009 LG Electronics. Inc. All right reserved.
Only for training and service purposes
Cause of error
• 1ph : DC link volt. is
140Vdc .
• 3ph : DC link volt. is
250Vdc .
• 1ph : DC link volt. is
140Vdc .
• 3ph : DC link volt. is
250Vdc .
❊ Check DC link voltage
❊ Check TRANS1
No
Correct
connection
No
Change
Compressor
❊ Dc link voltage table
No
Change
1 Phase AUUW243D[LUU245HV]
Compressor
- 75 -
Check point & Normal condition
• Check the power source.
• Check the components.
• Check the power source.
• Check the components.
CN_TRANS 1
Model
Type
Non operating
PFC
DC300V ¡¾ 10%
AUUW423D[LUU425HV]
PFC
DC300V ¡¾ 10%
5. Trouble Shooting
V
DC Link Voltage
Operating
DC380V ¡¾ 10%
DC380V ¡¾ 10%
LGE Internal Use Only