Part 2 Functions & Controls
<Ceiling Height Selection Table>
Ceiling Height Level
01
Low
02
Standard
03
High
04
Super high
❊
Ceiling height setting is available only for some products.
❊
Ceiling height of 'Super high' function may not exist depending on the indoor unit.
❊
Refer to the product manual for more details.
Copyright ©2009 LG Electronics. Inc. All right reserved.
Only for training and service purposes
1
Press
to enter the installer setting
mode until timer segment
display "01:01".
2
Repeat pressing
Function code 05.
Ex) Setting Ceiling Height as 'Standard'.
3
Select ceiling height value by pressing
button.
(01:Low, 02:Standard, 03:High,
04:Super high)
4
Press
5
Press
system will automatically exit
after 25 seconds without any
input.
Decrease the indoor airflow rate 1 step from standard level
Set the indoor airflow rate as standard level
Increase indoor airflow rate 1 step from standard level
Increase indoor airflow rate 2 steps from standard level
- 18 -
button for 4 seconds
button to select
Function Code
Ceiling height
button to save or release.
button to exit or
Description
LGE Internal Use Only