Outdoor Fan Control - LG Single A Svc Manual

Single "a"-inverter type
Hide thumbs Also See for Single A:
Table of Contents

Advertisement

6. Outdoor Fan Control

6.1 Function
Working of outdoor fan are different in different models.
Some models are single fan some are two fan type.
6.2 Operating process
Control logic of outdoor fan depends on outdoor temperature
1. DC motor fan control
Model
1 Pahse
AUUW243D[LUU245HV]
AUUW423D[LUU425HV]
Outdoor Temperature
41~46˚C
38~41˚C
28~38˚C
24~28˚C
18~24˚C
14~18˚C
9~14˚C
2~9˚C
-3~2˚C
Copyright ©2009 LG Electronics. Inc. All right reserved.
Only for training and service purposes
Base Step
670
670
Cooling Step
Outdoor Temperature
Base Step+2
Base Step+1
Base Step
Base Step-1
Base Step-2
Base Step-3
Base Step-4
Base Step-5
Base Step-6
- 41 -
Part 3 Control logic
RPM
Max Step
700
700
22~26˚C
18~22˚C
14~18˚C
10~14˚C
4~10˚C
0~4˚C
-4~0˚C
-8~-4˚C
-15~-8˚C
Min Step
200
200
Heating Step
Base Step-4
Base Step-3
Base Step-2
Base Step-1
Base Step
Base Step+1
Base Step+2
Base Step+2
Base Step+2
LGE Internal Use Only

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents