6.7 Check code Trouble shooting CH03
Display
Title
code
Communication Error
03
(Wired remote controller)
Check Flow Chart
Check the wire
connection(Open /
Short / Miswirring)
Is it normal ?
Yes
Is the soldering state
of connector is normal?
Yes
Check the volt. of main
PCB power source.
(DC 12V,DC 5V)
Is it normal ?
Yes
Check the installation of
wired remote controller.
(Noise interference)
Is it normal ?
Copyright ©2009 LG Electronics. Inc. All right reserved.
Only for training and service purposes
Cause of error
• Connector connection
error
• Faulty PCB / Remote
controller
• Connection wire break
No
Correct connection
Or change connection wire
No
Re-soldering component
Or change the PCB
No
Correct connection
Or change the PCB
No
Adjust the state
of installation
- 69 -
Check point & Normal condition
• Connection of wire
• Main PCB Volt. DC12V
• Noise interference
CN-REMO
Wired R/C
S
12V
GND
(YL)
(RD)
(BR)
12Vdc
V
Check the Volt.
5. Trouble Shooting
Indoor Unit
12V
S
GND
(RD)
(YL)
(BR)
12Vdc
V
Check the Volt.