Cleaning the separator roller
11. Pull the separator roller door forward and hold it in place while you
remove the separator roller by lifting it off the cradle.
12. Using a roller cleaning pad, scrub the separator roller tires in a side-
to-side motion. Rotate the roller to clean the entire surface.
13. Open and hold the separator roller door to reinstall the separator
roller. Align the separator roller correctly with the slots. Align the flat
end of the shaft with the slot in the cradle and gently seat the shaft,
which should fall into place. Do not apply pressure to seat the shaft
14. Gently release the separator roller door back in place. Verify that
the separator roller is seated level.
15. Close the transport cover and reset the maintenance reminder by
clicking on the Clean Feed Rollers hyperlink on the Maintenance
monitor.
16. Click Yes on the dialog box to confirm the feed rollers have been
cleaned. The reminder will be reset for the next required
maintenance session.
.