KODAK 9000 3D Extraoral Imaging System
User Guide

Advertisement

Table of Contents
loading

Summary of Contents for Kodak 9000

  • Page 1 KODAK 9000 3D Extraoral Imaging System User Guide...
  • Page 2 Notice Congratulations on your purchase of the KODAK 9000 Extraoral Imaging System. Thank you for your confidence in our products and we will do all in our power to ensure your complete satisfaction. The User Guide for the KODAK 9000 3D Extraoral Imaging System includes information both on the Panoramic features as well as the 3D features.
  • Page 3: Table Of Contents

    Kodak Dental Imaging Software Overview ........
  • Page 4 Contents Acquiring a TMJ x4 Image ..............5–6 Acquiring a 3D Image .
  • Page 5: 1-About This Guide

    CAUTION Alerts you to a condition that might cause serious damage. IMPORTANT Alerts you to a condition that might cause problems. NOTE Emphasizes important information. Provides extra information and hints. KODAK 9000 3D Extraoral Imaging System_User Guide (SM710)_Ed 01 1–1...
  • Page 6: Note To The User

    To use and operate your panoramic unit and your digital imaging software you must follow the instructions contained in this guide. Warning and Safety Instructions When operating the Kodak 9000 3D unit, observe the following warning and safety instructions: DANGER OF ELECTRIC SHOCK This is an electrical Unit.
  • Page 7 Ask the patient to remain still until the Unit arm has stopped moving and the RESET movement has completed. • DO NOT use this Unit in conjunction with oxygen-rich environments. This Unit is not intended for use with flammable anesthetics or flammable agents. KODAK 9000 3D Extraoral Imaging System_User Guide (SM710)_Ed 01 1–3...
  • Page 8: Marking And Labeling Symbols

    Marking and Labeling Symbols Marking and Labeling Symbols Type B device symbol complying with the IEC 60601-1 standard In the EEC, this symbol indicates: DO NOT discard this product in a trash receptacle; use an appropriate recovery and recycling facility. Contact your local sales representative for additional information on the collection and recovery programs available for this product...
  • Page 9: 2-Kodak 9000 3D Digital Imaging Unit Overview

    KODAK 9000 3D DIGITAL IMAGING UNIT OVERVIEW The KODAK 9000 3D digital imaging unit is compliant with the requirements of the EEC and international medical standards. The KODAK 9000 3D Unit has been designed to carry out the following radiological examinations: •...
  • Page 10 Control panel Generator Hand Grips Unit rotative arm Chin rest base X-Ray remote control Panoramic chin rest PC hosting the imaging and the acquisition software 3D chin rest and bite block 2–2 KODAK 9000 3D D IGITAL IMAGING UNIT OVERVIEW...
  • Page 11 Figure 2–3 KODAK 9000 3D Unit Positioning Laser Beam components 3D central positioning laser beam Mid-sagittal positioning laser beam Horizontal positioning laser beam 3D Field of View (FoV) positioning laser beam KODAK 9000 3D Extraoral Imaging System_User Guide (SM710)_Ed 01 2–3...
  • Page 12: Control Panel Overview

    Display Screen: Displays the current acquisition parameters and the error messages. Ready Indicator LED: Green indicates the Unit is ready for acquisition. X-Ray Emission LED: Yellow indicates x-rays are being emitted. System Status LED: Red indicates error alerts. 2–4 KODAK 9000 3D D IGITAL IMAGING UNIT OVERVIEW...
  • Page 13: X-Ray Remote Control Overview

    You must press and hold the exposure button until the end of acquisition. Premature release of the exposure button interrupts the acquisition. Figure 2–5 X-Ray Remote Control Exposure button: launches image acquisition. KODAK 9000 3D Extraoral Imaging System_User Guide (SM710)_Ed 01 2–5...
  • Page 14: Positioning Accessories And Replacement Parts

    Panoramic standard bite block Bite block for edentulous patients Single use sheaths for bite blocks (500 pcs box) Table 2–2 3D Positioning Accessories and Replacement Parts Accessory Description 3D bite block 3D chin rest 2–6 KODAK 9000 3D D IGITAL IMAGING UNIT OVERVIEW...
  • Page 15: 3-Imaging Software Overview

    Chapter 3 IMAGING SOFTWARE OVERVIEW PC System Requirements This section specifies the minimum PC system requirements for Kodak 9000 3D extraoral imaging system software. IMPORTANT It is MANDATORY to check that the PC system configuration is compatible with the PC system requirements for the Kodak 9000 3D software.
  • Page 16: General Software Overview

    • Acquisition interface module Kodak Dental Imaging Software The Kodak dental imaging software is a user-friendly working interface that was designed and developed specifically for radiological diagnosis. It is the common imaging platform for all our digital systems for dentistry.
  • Page 17: Kodak Dental Imaging Software Overview

    Kodak Dental Imaging Software Overview Patient Window Overview The Patient Window is the first window that appears when you launch the Kodak dental imaging software. This window is the main patient record management interface that provides you with all the patient record functions.
  • Page 18 Kodak Dental Imaging Software Overview Exit Exits the Patient window Picture Insert picture Inserts the patient picture Remove picture Removes the patient picture Utilities Reindex Regenerates all the index table Archival... Archives images before the given date Options Preferences... Configures the language and the...
  • Page 19: Imaging Window Overview

    New 3D image Accesses the 3D Acquisition Window for a 3D image History Open Opens the patient history record with image files Save Saves the acquired image Close Closes the patient image KODAK 9000 3D Extraoral Imaging System_User Guide (SM710)_Ed 01 3–5...
  • Page 20 Kodak Dental Imaging Software Overview Delete Deletes selected image Print Prints the patient image Print Setup Sets up the printing parameters Slide Show Displays a set of images in a particular sequence Report Creates customized letters Word Report Creates a report template...
  • Page 21 7 Contextual Toolbar: The toolbar type depends on the image type context. You can reposition the toolbar. NOTE For information and procedures on how to use these functions, from the menu bar click ? to access the online help. KODAK 9000 3D Extraoral Imaging System_User Guide (SM710)_Ed 01 3–7...
  • Page 22: 3D Imaging Windows Overview

    Kodak Dental Imaging Software Overview 3D Imaging Windows Overview The 3D Imaging Windows are the main imaging interfaces that provide you with the 3D imaging functions. 3D Home Page Window Figure 3–3 Title Bar: Displays Software name and version. Window Tabs: Provide access to the indicated Windows.
  • Page 23 Click to display the cut plane as colored planes. 3D Filters Click to apply the smooth filter. Click to configure the smooth filter settings. KODAK 9000 3D Extraoral Imaging System_User Guide (SM710)_Ed 01 3–9...
  • Page 24 Kodak Dental Imaging Software Overview Measurements Click to show or hide measurements. Click to measure the length. Click to measure the angle. Click to edit the measurements. Click to delete the measurements. Implant Click to show or hide all implants.
  • Page 25 Export Click to create a screen capture file. Click to access the screen capture file in the directory. Display options: Display the specific screen in different formats. KODAK 9000 3D Extraoral Imaging System_User Guide (SM710)_Ed 01 3–11...
  • Page 26 Kodak Dental Imaging Software Overview To access the , from the Home Page click the Oblique Slicing Window Oblique Slicing Window tab. Figure 3–6 Oblique Slicing Window Title Bar: Displays software name and version. Window Tabs: Provides access to the indicated windows.
  • Page 27 Click to access the screen capture file in the directory. Display options: Display the specific screen in different formats. NOTE Click to use the default value. KODAK 9000 3D Extraoral Imaging System_User Guide (SM710)_Ed 01 3–13...
  • Page 28: Acquisition Interface Module

    Acquisition Interface Module Acquisition Interface Module Panoramic Acquisition Window Overview The Panoramic Acquisition Window is the main panoramic interface with the Kodak 9000 3D extraoral imaging system that provides you with imaging acquisition functions. Panoramic Acquisition Window Figure 3–7 Information button: identifies: •...
  • Page 29 The Selector button enables you to access the following 3 panes: • Program pane: Examination type options • Patient pane: Patient type parameter options • Parameters pane: Exposure parameter options KODAK 9000 3D Extraoral Imaging System_User Guide (SM710)_Ed 01 3–15...
  • Page 30: Panoramic Program Pane

    Acquisition Interface Module Panoramic Program Pane The Panoramic Program pane enables you to choose different radiological exams. The diagram in the Panoramic Program pane represents a jaw, with the right side of the diagram corresponding to the right side of the patient. Click on a section of the jaw to select an anatomical zone for radiological exam.
  • Page 31: Panoramic Patient Pane

    Click for a normal dental arch. Click for a sharp dental arch. Incisors orientation: Click for a vestibular orientation. Click for an axial orientation. Click for a lingual orientation. KODAK 9000 3D Extraoral Imaging System_User Guide (SM710)_Ed 01 3–17...
  • Page 32: Panoramic Parameter Pane

    Acquisition Interface Module Panoramic Parameter Pane The Panoramic Parameter pane enables you to choose exposure parameters for the radiological image acquisition. You must adapt the parameter settings to the patient type. Figure 3–10 Panoramic Parameter Pan Fine-tuning buttons: Click to fine-tune the kV and click to fine-tune the mA.
  • Page 33: 3D Acquisition Window Overview

    Acquisition Interface Module 3D Acquisition Window Overview The 3D Acquisition Window is the main 3D interface with the Kodak 9000 3D extraoral imaging system that provides you with imaging acquisition functions. 3D Acquisition Window Figure 3–11 Information button: identifies: •...
  • Page 34 Acquisition Interface Module Exit button: Closes the Acquisition Window. X-Ray Emission Indicator: Yellow indicates the x-ray emission status. Selector button: Selects different acquisition setting options. • Click Program to select examination type options • Click Patient to select patient type parameters •...
  • Page 35: 3D Program Pane

    Rotative Arm Position Indicator: Indicates the rotative arm position, using the 3D central positioning laser beam. Click to validate the region of interest selection. Click to cancel the region of interest selection. KODAK 9000 3D Extraoral Imaging System_User Guide (SM710)_Ed 01 3–21...
  • Page 36: 3D Patient Pane

    Acquisition Interface Module 3D Patient Pane The 3D Patient pane enables you to choose different patient parameters. The selection of the patient parameters influences the quality of the image. The selected parameters must be based on the patient age and morphology. Figure 3–13 Panoramic Patient Pane Patient corpulence parameters:...
  • Page 37: 3D Parameter Pane

    You must adapt the parameter settings to the patient type. Figure 3–14 3D Parameter Pane. Fine-tuning buttons: Click to fine-tune the kV and click to fine-tune the mA. Radiation dose options: Kilovolt milliampere KODAK 9000 3D Extraoral Imaging System_User Guide (SM710)_Ed 01 3–23...
  • Page 38 Acquisition Interface Module 3–24 IMAGING SOFTWARE OVERVIEW...
  • Page 39: 4-Getting Started

    To start your imaging software, follow these steps: 1. On your desktop, double-click From your PC, click Start > All Programs > Kodak > Kodak Dental Software. Blank Patient Window is displayed. 2. Create or open an existing patient record.
  • Page 40: Accessing The Acquisition Windows

    Accessing the Acquisition Windows 2. Enter the required patient information. The Last name, the First name and the Date of birth fields are required. 3. From the menu bar, select Picture > Insert Picture to add a *.tif or *.bmp picture of the patient to the record.
  • Page 41: 5-Acquiring Images

    4. Position the appropriate chin rest on the chin rest support and cover the bite block with a hygienic barrier. If needed, use the edentulous bite block. Press and hold to raise the chin rest to the maximum height. KODAK 9000 3D Extraoral Imaging System_User Guide (SM710)_Ed 01 5–1...
  • Page 42: Preparing And Positioning The Patient

    Acquiring a Panoramic, TMJ x2 or Sinus Image Preparing and Positioning the Patient To prepare and position the patient, follow these steps: 1. Ask the patient to remove all metal objects. 2. Ask the patient to wear a lead apron. Ensure that the apron lays flat across the patient shoulders.
  • Page 43 OFF automatically. IMPORTANT The spinal column and the nose of the patient must be aligned in a straight line (1). 6. Immobilize the patient head with the temple supports (3). KODAK 9000 3D Extraoral Imaging System_User Guide (SM710)_Ed 01 5–3...
  • Page 44: Launching The X-Ray

    Acquiring a Panoramic, TMJ x2 or Sinus Image 7. Ask the patient to close the eyes, to remain still, to swallow, to place the tongue in contact with the palate and to breath through the nose. Launching the X-ray To launch the x-ray, follow these steps: 1.
  • Page 45 4. Do the following when the acquisition is finished: • Open the temple supports and release the patient. • Remove the hygiene barrier of the bite block. • Reset the Unit rotative arm for the next acquisition. KODAK 9000 3D Extraoral Imaging System_User Guide (SM710)_Ed 01 5–5...
  • Page 46: Acquiring A Tmj X4 Image

    Acquiring a TMJ x4 Image Acquiring a TMJ x4 Image Before acquiring a TMJ x4 image, check that you have: • Reset the Unit rotative arm to start position for patient entry • Selected the patient record • Accessed the Imaging Window •...
  • Page 47: Acquiring A 3D Image

    To prepare and position the patient, follow these steps: 1. Ask the patient to remove all metal objects. 2. Ask the patient to wear a lead apron. Ensure that the apron lays flat across the patient shoulders. KODAK 9000 3D Extraoral Imaging System_User Guide (SM710)_Ed 01 5–7...
  • Page 48 Acquiring a 3D Image 3. Ask the patient to enter the Unit. On the Control Panel, press and hold to adjust the Unit to the patient height. 4. Ask the patient to do the following: • Stand up straight or sit on a stool. •...
  • Page 49 3D FoV (2) positioning laser beam. Tighten the temple supports (3). 8. Ask the patient to close the eyes, to remains still and to breath through the nose. KODAK 9000 3D Extraoral Imaging System_User Guide (SM710)_Ed 01 5–9...
  • Page 50: Launching The X-Ray

    Acquiring a 3D Image Launching the x-ray To launch the x-ray, follow these steps: 1. Leave the x-ray room and close the door. You must keep eye contact with the patient during acquisition. IMPORTANT To stop the acquisition, if any problem, release the exposure button of the remote control or press the red emergency stop button.
  • Page 51: Manually Pre-Setting The Patient Positioning

    Unit rotative arm. 4. Remove the plaster imprint and position the patient in the Unit and follow the appropriate steps to acquire the 3D image of the region of interest. KODAK 9000 3D Extraoral Imaging System_User Guide (SM710)_Ed 01 5–11...
  • Page 52 Acquiring a 3D Image 5–12 ACQUIRING IMAGES...
  • Page 53: Daily

    Wipe the Unit with a dry cloth at the end of each day's operation. WARNING Do not use detergents or solvents to clean the outer covers of the Unit. Monthly Wipe the outer covers of the unit with a soft, dry cloth. KODAK 9000 3D Extraoral Imaging System_User Guide (SM710)_Ed 01 6–1...
  • Page 54: Annually

    Annually Annually We recommend a general inspection of the Unit carried out by an authorized service technician. 6–2 MAINTENANCE...
  • Page 55: 7-Technical Specifications

    Chapter 7 TECHNICAL SPECIFICATIONS Compliance with International Standards The KODAK 9000 3D digital imaging Unit is compliant with the International and EEC standards. Manufacturer TROPHY A subsidiary of Carestream Health, Inc. 4, Rue F. Pelloutier, Croissy-Beaubourg 77435 Marne la Vallée Cedex 2, France Model KODAK 9000 3D Unit, KODAK 9000 Unit.
  • Page 56: Unit Technical Specifications

    Unit Technical Specifications Unit Technical Specifications Table 8-1 describes the technical specifications for the KODAK 9000 3D digital imaging unit and Kodak 9000 digital imaging unit. Table 7–1 Unit Technical Specification Kodak 9000 3D Kodak 9000 X-Ray Generator Tube voltage...
  • Page 57 1158mm (L) x 1595mm (D) x 2378mm (H)* * Unit with shorter column is available on special order Required space 1500 (L) x 2000 (D) x 2400 (H) mm Weight 160 kg (353 lb KODAK 9000 3D Extraoral Imaging System_User Guide (SM710)_Ed 01 7–3...
  • Page 58: Unit Electronic Specifications

    Unit Electronic Specifications Unit Electronic Specifications 230/240 V (± 10%) 50/60 Hz, 100/110/130V (± 10%) 50/60 Hz, Type of Electrical Power Supply Single-Phase Single-Phase Acceptable fluctuation ± 10% ± 10% Ω Ω Apparent resistance of the power (max.) 0.12 (max.) supply circuit Permanent absorbed current 0.45 A...
  • Page 59: X-Ray Generator Technical Specifications

    Radiation leakage after one hour's operation (maximum utilization rate of < 1 mGy 93W, i.e. 90 kV, 10 mA, 13.9 sec. every 2 minutes 15 sec.) Weight 8.2 kg Dimensions 235 x 245 x 120 mm KODAK 9000 3D Extraoral Imaging System_User Guide (SM710)_Ed 01 7–5...
  • Page 60 X-Ray Generator Technical Specifications Figure 7–1 Heating and Cooling Curves of the X-ray Generator. Heating and cooling curves 110, 0 100, 0 90, 0 80, 0 100 W 70, 0 66 W 60, 0 33 W 50, 0 15 W 40, 0 10 W 30, 0...
  • Page 61 X-Ray Generator Technical Specifications Figure 7–2 Heating and Cooling Curves of the X-ray Tube Figure 7–3 Single Load Chart of the X-ray Tube Figure 7–4 Filament Emissions of the X-ray Tube KODAK 9000 3D Extraoral Imaging System_User Guide (SM710)_Ed 01 7–7...
  • Page 62 X-Ray Generator Technical Specifications 7–8 TECHNICAL SPECIFICATIONS...