Packings - WAGNER ProSpray 3.29 Operating Manual

Airless high-pressure spraying unit
Hide thumbs Also See for ProSpray 3.29:
Table of Contents

Advertisement

14. Unscrew lower housing (Fig. 13, Item 10) with adjusting
wrench while holding the upper housing (11) securely with
a second adjusting wrench.
15. Remove bearing ring (13) and O-ring (12).
16. Screw out outlet valve housing (14) from the piston (15)
with 3/8 inch hexagon socket head wrench.
17. Remove the upper seal (16), upper ball guide (17), outlet
valve ball (18), washer (19) and outlet valve seating (20).
18. Clean all the parts with the corresponding cleaning agent.
Check outlet valve housing (14), outlet valve seat (20),
outlet valve ball (18) and upper ball guide (17) for wear
and replace parts if necessary. If the worn outlet valve
seat (20) is unused on one side, install it the other way
around.
19. Carry out installation in the reverse order.
Lubricate O-ring (12) with machine grease and ensure
proper seating in the lower housing (10).
11
16
17
18
19
20
14
12
13
10
11.3

Packings

1. Remove inlet valve housing in accordance with the steps
in Chapter 11.2, Page 16.
2. It is not necessary to remove the outlet valve.
3. Loosen lock nut (Fig. 14, Item 5) counterclockwise with
light blows from a hammer.
4. Unscrew upper housing (6) counterclockwise from the
gear unit housing.
5. Clamp upper housing (6) at the wrench surfaces vertically
in a vice.
Do not tighten vice excessively to prevent
crushing.
Attention
6. Screw out threaded joint (7).
7. Slide the piston rod (4) forward until the piston is out of the
T-slot (2) on the slider assembly (3).
ProSpray 3.29 • 3.31
GB
8. Push piston (4) downward out of the upper housing (6).
9. Remove upper packing (8) and lower packing (9) from the
Attention
15
10. Remove the transportation devices from the upper and
11. Lubricate upper packing (8) and lower packing (9) with
17
Check piston for wear and replace if necessary.
upper housing (6).
Do not damage inside of upper housing.
lower packings. (The transportation device from the upper
packing is required for installation of the piston.)
machine grease.
Repairs at the unit
1
3
2
5
7
10
8
6
9
11
4

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Prospray 3.31

Table of Contents