Address 88 = Enhanced SDI Path 1
Address 89 = Enhanced SDI Path 2
Address 90 = Enhanced SDI Path 3
Address 91 = Enhanced SDI Path 4
The trouble condition is also sent through a
backup path to the central station as
Communication Trouble SDI ##, using the same
virtual address numbers as the trouble
messages. The communication trouble event also
creates new Modem IIIa
central station might need to add to their
automation software. Refer to Events 157 to 160
in the Modem IIIa
2
Messages section of the
Appendix in the D6600 Computer Interface Manual
(P/N: 4998122703) for the details of central
station data changes.
2.6.2
ANSI/SIA CP-01 Compliance in Version
7.05
Minimum system requirements for
Classification in accordance with
ANSI/SIA CP-01-2000:
UL Listed and Classified control
unit Model D9412GV2, D7412GV2,
or D7212GV2
UL Listed and Classified keypad
Model D1256, D1257, D1260,
D1255, D1255R, or D1255 RW
UL Listed Local Bell
© 2013 Bosch Security Systems, Inc.
2
messages that the
D9412GV2/D7412GV2 Release Notes for Version 7.09
D9412GV2/D7412GV2
Exit Delay Warning
Prompt:
A# Exit Warning
When enabled, the Exit Delay tone at all keypads
in an area about to arm is replaced by a fast
Trouble Tone for the last ten seconds. The Alarm
Bell output also pulses ON and OFF for the last
ten seconds of the Exit Delay.
Entry Delay Warning
A# Entry Warning
Prompt:
When enabled, the Alarm Bell output pulses ON
and OFF for the last ten seconds of the Entry
Delay.
Exit Time Restart
A# Exit Restart
Prompt:
When enabled, this feature causes an area's Exit
Delay timer to restart upon re-entry. To consider
the area as vacated, the control panel must
detect a point with a delay alarm response
changing from normal to off-normal, and back to
normal. When vacated, a fault on any point with a
delay alarm response during the remaining Exit
Delay causes the countdown to restart from the
beginning.
Exit Error
If a point with a delay alarm response remains
off-normal when the Exit Delay expires, the Entry
Delay starts. If the system is not disarmed within
the programmed time, an Exit Error Alarm is
generated. This feature is always enabled and
has no configuration parameters.
The alarm with an exit error event creates a new
2
Modem IIIa
message that the central station
might need to add to their automation software.
Refer to Event 38 in the Modem IIIa
section of the Appendix in the
ConettixD6600/D6100 Computer Interface Manual
(P/N: 4998122703) for the details of central
station data changes.
Page 9
2
Messages