nifty Heightrider HR17 SP50 HYBRID SERIES 4x4 Operating/Safety Instructions Manual page 28

Height rider/sp series
Table of Contents

Advertisement

Height Rider/SP Series
Operating & Safety Instructions
7)
To return control to the platform, turn base control key-switch to the Platform position (fully
clockwise).
8)
When not in use return machine to stowed position, turn the base control key-switch anti-
clockwise to the OFF position, remove key and chock wheels.
EMERGENCY PROCEDURES
1)
Push in red emergency stop to shut down all functions.
2)
In the event that the controls fail or the operator becomes incapacitated the booms can be
operated by using the manual hand pump which is located under the canopy adjacent to the
base controls. To operate:
a)
b)
c)
26
Move and hold control lever required.
Operate hand pump handle to move machine.
Release control lever to halt machine movement.
English/USA – 03/10