Note; During normal machine usage with the engine running, the batteries are on continuous recharge
The exception to this is when the control system decides that additional electric power is required in
order to maintain drive/function speed. If the operator is using electric power only and a low battery
warning has activated, it is advisable to start the engine, enabling continued use of the machine, whilst
at the same time recharging the batteries.
BATTERY ISOLATOR: - The battery-disconnect handle is located adjacent to the links cylinder,
between both engine and control canopies. In order to isolate the machine control and power circuits
from the batteries it is necessary to pull the release handle, which disconnects the supply to the entire
control system. Under normal operation, the machine key switch should be used to isolate the
machine, with the battery isolator handle only being required for emergencies, in the event of a short
circuit, or during routine maintenance.
4.1.5
DUTY SELECTOR: -
unless the diesel engine has been started.
4.1.6
FUSES & TRIP SWITCHES: -
Power Tray
35A Circuit breaker inside ABS box
2 x 10A Circuit breaker inside ABS box
Ground Control Station
125A Fuse on battery terminal
4 x 15A blade fuses inside Ground Control Box
1 x 2A blade fuse inside Ground Control Box
1 x 15A Circuit breaker
1 x 80A Fuse
English/USA – 03/10
Original instructions
On multiple power option machines, the machine will default to electric power
Height Rider/SP Series
Operating & Safety Instructions
Chassis
325A Fuse inside base
2A Circuit breaker inside box
Platform Control Station
2 x 15A blade fuses behind Control Panel
2 x 2A blade fuses behind Control Panel