Table Of Test Equipment And Tools; Adjusting The Feeder Pressure; Confirming The Separation Spring - Panasonic KX-FP101AL Service Manual

Compact plain paper fax
Hide thumbs Also See for KX-FP101AL:
Table of Contents

Advertisement

3 ADJUSTMENTS
3.1.

TABLE OF TEST EQUIPMENT AND TOOLS

No.
1
2
3.2.

ADJUSTING THE FEEDER PRESSURE

If misfeeding of a document such as multiple feeding or no feeding occurs frequently, try to adjust the feeder pressure by following
the steps below.
1. Slide the cover open lever forwards to open the front cover.
2. Shift the position of the lever by using an instrument with a pointed end like a clip or a ball-point pen.
Position A: Select this position when documents are not fed.
Position B: Standard position (pre-selected)
Position C: Select this position when documents are multiple-fed.
3. Close the front cover securely by pushing down on both ends.
3.3.

CONFIRMING THE SEPARATION SPRING

1. Open the front cover.
2. Check the highest level of the separation spring with the spring height tool. Please make sure that the separation spring does
not touch the tool during this operation. (Both right and left) (See Fig. 1.)
Note:
Be careful not to bend the separation spring.
Test Equipment and Jig Name
Oscilloscope
Extension Cord
Fig. 1
101
Jig No.
--------
PQZZ2K12Z, PQZZ8K18Z
KX-FP101AL