6. SPECIFICATIONS OF ELECTRICAL PARTS

6-1. Indoor Unit
No.
Parts name
1
Fan motor (for indoor)
2
Room temp. sensor (TA-sensor)
3
Heat exchanger temp. sensor (TC-sensor)
4
Louver motor
6-2. Outdoor Unit
No.
Parts name
1
Reactor
2
Outdoor fan motor
3
Suction temp. sensor (TS sensor)
4
Discharge temp. sensor (TD sensor)
5
Outside air temp. sensor (TO sensor)
6
Heat exchanger temp. sensor (TE sensor)
Terminal block (5P)
7
8
Compressor
9
Coil for PMV
10
Coil for 4-way valve
RAS-18N3AV-E
RAS-22N3AV-E
CAM-MD12TCTH-5
RAS-18N3AV-E
RAS-22N3AV-E
Model name
MF-340-30-3
DC340V, 30W
( — )
10kΩ at 25°C
( — )
10kΩ at 25°C
MSBPC20F04
DC12V, 4phase, 16pole
Model name
CH-57-Z-T
L = 10mH, 16A
ICF-140-43-4R
DC140V, 43W
(Inverter attached)
10kΩ (25°C)
(Inverter attached)
62kΩ (20°C), 3.3kΩ (100°C)
(Inverter attached)
10kΩ (25°C)
(Inverter attached)
10kΩ (25°C)
JXO-5B
20A, AC250V
DA131S1B-31FZ
3phases 4poles 1100W
DA150A1F-20F
DC12V
STF-01AJ646A1
AC220–240V
STF-01AJ503K1
18
FILE NO. SVM-12071
Rating
Rating

Hide quick links: