PRECAUTIONS FOR SAFETY
DANGER
• Do not install, repair, open or remove the cover. It may expose you to dangerous
voltages. Ask the dealer or the specialist to do this.
• Turning off the power supply will not prevent potential electric shock.
• The appliance shall be installed in accordance with national wiring regulation.
• Means for disconnection from the supply having a contact separation of at least
3 mm in all poles must be incorporated in the fixed wiring.
WARNING
• Do not expose your body directly to cool air for a long time.
• Do not insert your finger or any article into the air inlet/outlet.
• When an abnormality (burning smell, etc.) occurs, stop the air conditioner and
disconnect the power supply or turn off the breaker.
CAUTION
• Do not wash the unit with water. It may cause an electric shock.
• Do not use this air conditioner for other purposes such as preserving food, breeding
animal, etc.
• Do not step or put anything on the indoor/outdoor unit. It may cause an injury or
damage the unit.
• Before cleaning the unit, turn off the main switch or the circuit breaker.
• When the unit won't be used for a long time, turn off the main switch or the circuit
breaker.
INDOOR UNIT DISPLAY
1 Hi POWER (Green)
2 FILTER (Orange)
3 PRE.DEF or FAN-ONLY (Orange)
4 TIMER (Yellow)
5 OPERATION (Green/*Orange)
* Orange : Auto Restart Operation
(Heating model)
Hi POWER FILTER
PRE.DEF
TIMER
OPERATION
+
+
+
+
+
1 2 3 4
5
(Cooling model)
Hi POWER FILTER
FAN-ONLY
TIMER
OPERATION
+
+
+
+
+
PREPARATION BEFORE USE
Preparing Filters
1. Open the air inlet grille and remove the air filters.
2. Attach the filters. (see detail in installation manual)
Loading Batteries
1. Remove the cover. Insert 2 new batteries (AAA type) following
the (+) and (–) positions.
1
2. Push RESET : Adjust the clock.
2.1 Push CLOCK (adjust only).
2.2 Press
and
: Set the current time.
2.3 Press
: Start the clock.
3. Place the cover back.
Remote Control Location
7 m
• Max. 7 m from the indoor unit
AIRFLOW DIRECTION
1. Press
: Move the louver in the desired vertical direction.
2. Press
: Swing the air automatically and press again to stop.
3. For horizontal direction, adjust manually.
Note:
• Use only the
button to move the louver.
1
2
3
REMOTE CONTROL FUNCTION
1 Infrared signal emitter
2 Start/Stop button (
)
3 Mode select button (MODE)
1
4 Temperature button (TEMP.)
5 Fan speed button (FAN)
6 Auto louver button (SWING)
7 Set louver button (FIX)
8 On timer button (ON)
$
9 Off timer button (OFF)
%
! Sleep timer button (SLEEP)
2
" Reserve button (SET)
)
6
# Cancel button (CLR)
7
$ Memory and Preset button (PRESET)
8
% Automatic operation button (AUTO)
!
& High power button (Hi POWER)
( Economy button (ECO)
) Quiet button (QUIET)
~ Comfort sleep button (COMFORT SLEEP)
AUTOMATIC OPERATION (AUTO)
To automatically select cooling, heating, or fan only operation and control fan speed and
a louver
1. Press
.
2. Press
: Set the desired temperature.
AUTOMATIC OPERATION (AUTO CHANGEOVER: A)
To automatically select cooling, heating, or fan only operation
1. Press
: Select A.
2. Press
: Set the desired temperature.
COOLING / HEATING / FAN ONLY OPERATION
1. Press
: Select Cool
, Heat
, or Fan only
.
2. Press
: Set the desired temperature.
Cooling: Min. 17°C, Heating: Max. 30°C, Fan Only: No temperature indication
3. Press
: Select AUTO, LOW , LOW+
, MED
HIGH
.
DRY OPERATION (COOLING ONLY)
For dehumidification, a moderate cooling performance is controlled automatically.
1. Press
: Select Dry
.
2. Press
: Set the desired temperature.
Hi POWER OPERATION
To automatically control only room temperature, airflow and operation mode for faster
cooling or heating operation (except in DRY, FAN ONLY and ON TIMER mode)
1. Press
: Start and stop the operation.
2. Press
: Set the desired temperature.
ECO OPERATION
To automatically control room temperature, fan speed and operation mode to save energy
(except in DRY, FAN ONLY and ON TIMER mode)
1. Press
: Start and stop the operation.
5
Note: Under certain conditions, ECO mode may not provide adequate heating or cooling
4
due to energy saving features.
3
~
&
TEMPORARY OPERATION
(
#
In case of the misplaced or discharged remote control
9
• Pressing the TEMPORARY button, the unit can start or stop without using the remote
"
control.
TEMPORARY button
TIMER OPERATION
Setting the ON Timer
1. Press
: Set the desired ON timer.
2. Press
: Set the timer.
3. Press
: Cancel the timer.
Setting the OFF Timer
1. Press
: Set the desired OFF timer.
2. Press
: Set the timer.
3. Press
: Cancel the timer.
Every timer allows the user to set both the ON & OFF timers and will be activated
on a daily basis.
Setting Combined Timer
1. Press
: Set the ON timer.
, MED+
, or
2. Press
: Set the OFF timer.
3. Press
.
4. Press
button during the (
or ) mark flashing.
• During the every day timer is activating, both arrows (
Note:
• Keep the remote control in accessible transmission to the indoor unit; otherwise,
the time lag of up to 15 minutes will occur.
• The setting will be saved for the next same operation.
PRESET OPERATION
Set your preferred operation for future use. The setting will be memorized by the unit for
future operation (except airflow direction).
1. Select your preferred operation.
2. Press and hold
for 3 seconds to memorize the setting. The
3. Press
: Operate the preset operation.
AUTO RESTART OPERATION
To automatically restart the conditioner after the power failure (Power of the unit must be
on.)
Setting
1. Push and hold the TEMPORARY button for 3 seconds to set the operation
(operation lamp : orange).
• Do not operate on TIMER operation.
2. Push and hold the TEMPORARY button for 3 seconds to cancel the operation
(operation lamp : green).
, ) are indicated.
mark displays.
Continue

Advertisement

loading

Summary of Contents for Toshiba RAS-18 NKHP Series

  • Page 1 Loading Batteries ENGLISH AUTOMATIC OPERATION (AUTO) TIMER OPERATION 1. Remove the cover. Insert 2 new batteries (AAA type) following To automatically select cooling, heating, or fan only operation and control fan speed and Setting the ON Timer the (+) and (–) positions. PRECAUTIONS FOR SAFETY a louver 1.
  • Page 2 DECLARATION OF CONFORMITY (Cooling models) • This function cannot use with Inverter model. We, TOSHIBA CARRIER (THAILAND) CO., LTD., 144/9 Moo 5, Bangkadi Industrial Park, Tivanon Road, RAS-18, 24 NKP Series / 18, 24 NA Series Tambol Bangkadi, Amphur Muang, Pathumthani, 12000, Thailand, declare under our responsibility that the...

This manual is also suitable for:

Ras-24 nkhp seriesRas-18nah seriesRas-24 nah seriesRas-18 nkp seriesRas-24 nkp seriesRas-18 na series ... Show all