10-3. Indoor Unit

10-3-1. Installation Place
• A place which provides the spaces around the
indoor unit as shown in the diagram.
• A place where there are no obstacle near the air
inlet and outlet.
• A place which allows easy installation of the piping
to the outdoor unit.
• A place which allows the front panel to be opened.
• The indoor unit shall be installed as top of the indoor
unit comes to at least 2 m height. Also, it must be
avoided to put anything on the top of the indoor
unit.
CAUTION
• Direct sunlight on the indoor unit's wireless
receiver should be avoided.
• The microprocessor in the indoor unit should
not be too close to RF noise sources.
(For details, see the owner's manual.)
<Remote control>
A place where there are no obstacles such as a
curtain that may block the signal from the remote
control.
Do not install the remote control in a place
exposed to direct sunlight or close to a heating
source such as a stove.
Keep the remote control at least 1 m apart from
the nearest TV set or stereo equipment. (This is
necessary to prevent image disturbances or noise
interference.)
The location of the remote control should be
determined as shown below.
(Side view)
(Top view)
Remote
Reception
control
range
Fig. 10-3-1
Indoor unit
Remote
control
10-3-2. Cutting a Hole and Mounting
Installation Plate
<Cutting a hole>
When install the refrigerant pipes from the rear.
35
The center of the pipe hole is above
the arrow
1. After determining the pipe hole position on the
installation plate (
(∅ 65 mm) at a slight downward slant to the
outdoor side.
NOTE :
• When drilling a wall that contains a metal lath,
wire lath or metal plate, be sure to use a pipe hole
brim ring sold separately.
<Mounting the installation plate>
17 0
To unit out line
240mm
85
Hook
Pipe hole
Indoor unit
– 52 –
FILE NO. SVM-12071
23 mm
120
180
240
Pipe hole
∅65 mm
.
Fig. 10-3-2
ð
) drill the pipe hole
Anchor bolt holes
Hook
To unit out line
240mm
To unit out line
35mm
To unit out line
120mm
240
180
120
35
23
0
Hook
7
Mounting
Thread
screw
Weight
Fig. 10-3-3
Pipe hole (∅65 mm)
1