13. Self-Cleaning
• Self-Cleaning diagram
function
Operation display
FCU fan
FCU louver
Timer display
Compressor
depend on presetting per room temperature.
CDU fan
depend on presetting per room temperature.
14. Remote
Setting the remote controller
Controller-A or
To separate using of remote controller for each indoor
B selection
unit in case of 2 air conditioner are installed nearly.
Remote Control B Setup.
1. Press [RESET] button on the indoor unit to turn the
air conditioner ON.
2. Point the remote control at the indoor unit.
3. Push and hold [CHECK] button on the Remote Control
by the tip of the pencil. "00" will be shown on
the display (Picture
4. Press [MODE] during pushing [CHECK]. "B"
will show on the display and "00" will disappear
and the air conditioner will turn OFF. The Remote
Control B is memorized [Picture
NOTE : 1. Repeat above step to reset Remote
Operation flow and applicable data, etc.
ON
ON
rpm is depend on presetting.
OPEN
ON or OFF
depend on presetting of timer function.
ON or OFF
ON or OFF
Cool mode or dry mode
operation more than 10 mins.
1
).
Control to be A.
2. Remote Control A has not "A" display.
3. Default setting of Remote Control from
factory is A.
1
OFF
ON
(500RPM)
OPEN (12.7°)
ON
OFF
OFF
Self-Cleaning
mode operate
30 mins.
Turn off by
Automatically
remote controller or
turn-off.
timer-off function.
2
).
2
39
FILE NO. SVM-12071
Description
OFF
OFF
CLOSE
ON or OFF
depend on presetting of timer function.
OFF
OFF
Operation time
1. Purpose
This operation is to operate only
one indoor unit using one remote
controller.
2. Description
When operating one indoor unit in
a situation where two indoor units
have been installed in the same
room or nearby rooms, this
operation prevents the remote
controller signal from being
received simultaneously by both
units, thus preventing both units
from operating.
3. Operation
The indoor unit on which the
remote controller selection has
been set to B receives the signal of
the remote controller also set to B.
(At the factory the remote controller
selection is set to A on all the
indoor units.
There is no A setting display.)