Oki Data CONFIDENTIAL
Error code
Cause
C3EA~
The ID unit
C3ED
fuse has
blown out.
(C3EA=Y,
C3EB=M,
C3EC=C,
C3ED=K)
C3E2
The fuse has
blown out.
C4C0
The fuse has
blown out.
C3B3~
Toner sensor
C383
detection
error.
(C3B3=Y,
C3A3=M,
C393=C,
C383=K) This
error does
not occur with
the default
settings.
C44A
Thermistor
Slope Error
45376001TH Rev.1
Error details
Remedial measure
Is the ID unit installed normally?
No
Re-install the ID unit.
Does this error recur?
Turn on the power
Does the printer recover from
again.
Yes
the error when the PU/PRZ
After checking
Yes
board is replaced?
for the sure
connection of the
cable between
PRZ board and PU
No
board, replace the
PRZ board.
Replace the PU
board.
Is the belt unit connected
No
Re-install the belt
normally?
unit.
Yes
Turn on the power
again.
Does this error recur?
Yes
After checking
for the sure cable
connection,
replace the PU or
Board IBY.
Is the fuser unit installed
No
After cleaning
normally?
the connecting
connector of the
fuser unit, re-install
the fuser unit.
Turn on the power
again.
Does this error recur?
Yes
After checking
for the sure cable
connection,
replace the PU or
Yes
Board IBY.
Is the toner cartridge installed?
No
Install the toner
cartridge.
Is the lock lever of the toner
No
Rotate the lock
set?
lever of toner to the
lock position.
Turn on the power
again.
Yes
Replace the toner
Does this error recur?
sensor assembly.
Is the error message displayed?
Turn on the power
Does this error recur?
again.
Yes
After leaving a
printer for 30
minutes, turn on
the power again.
Error code
Cause
C41E
Compensation
Is the error message displayed?
Thermistor
Does this error recur?
Error
C41A
Short-circuit
or open-
C41B
circuit of fuser
Does this error recur?
thermistor is
detected.
C449
The fuser
thermistor
C446
has detected
Does this error recur?
an abnormal
temperature
Does this error recur?
(high
temperature
or low
temperature.)
C41C
The backup
roller
thermistor is
Does this error recur?
detected of its
short-circuit.
(At high
temperature)
C41D
The backup
roller
thermistor
Does this error recur?
is detected
of its open-
circuit. (At low
temperature)
C468
The backup
roller
C466
thermistor
Does this error recur?
has detected
an abnormal
Does this error recur?
temperature
(high
temperature
or low
temperature.)
7. Troubleshooting and repair procedure
Error details
Remedial measure
Turn on the power
again.
After leaving a
Yes
printer for 30
minutes, turn on
the power again.
Turn on the power
again.
Yes
Replace the fuser
unit.
Turn on the power
again.
Yes
Replace the fuser
unit.
Yes
Replace the low
voltage power
supply unit.
Turn on the power
again.
Yes
Replace the fuser
unit.
Turn on the power
again.
Yes
Replace the fuser
unit.
Turn on the power
again.
Yes
Replace the fuser
unit.
Yes
Replace the low
voltage power
supply unit.
155 /