Oki MC760 Maintenance Manual page 124

Hide thumbs Also See for MC760:
Table of Contents

Advertisement

Oki Data CONFIDENTIAL
• During printing, the following messages are displayed.
P=***
W=***
P : Number of test print copies (unit: copies)
W : Print waiting time (unit: second)
• Displays are switched by pressing the [2] key.
T=*** U=***[###]
H=***%L=***[###]
U : *** = Upper heater temperature measurement value [unit:
[***] = Print execution target temperature [unit:
L : *** = Lower heater temperature measurement value [unit:
[###] = Lower thermistor read-out AD value [unit: HEX]
T : Environment temperature measurement value [unit:
H : Environment humidity measurement value [unit: % ]
• Displays are switched by pressing the [2] key.
KTR=*.** YTR=*.**
MTR=*.** CTR=*.**
YTR, MTR, CTR and KTR indicate the transfer voltage setting value for each
color (unit: KV)
• Displays are switched by pressing the [2] key.
KR=*.** YR=*.**
MR=*.** CR=*.**
KR : BLACK transfer roller resistance value [unit: uA]
YR : YELLOW transfer roller resistance value [unit: uA]
MR : MAGENTA transfer roller resistance value [unit: uA]
CR : CYAN transfer roller resistance value [unit: uA]
45376001TH Rev.1
• Displays are switched by pressing the [2] key.
• Displays are switched by pressing the [2] key.
]
]
]
]
• Displays are switched by pressing the [2] key.
• Displays are switched by pressing the [2] key.
ETMP=***UTMP=***
REG=****EXT=***
ETMP : Hopping motor constant speed correction parameter
(environment temperature) [unit: DEC]
UTMP : Fuser motor constant speed correction parameter
(fuse target temperature) [unit: DEC]
REG
: Hopping motor constant speed timer value (I/O setting value)
[unit: HEX)
EXT
: Fuse motor constant speed timer value (I/O setting value) [unit: HEX]
ID=****
KID, YID, MID and CID are the constant speed timer value of the respective ID
motors (I/O setting value) [unit: HEX]
BELT=****
FRM [***] ( xxx )
BELT : Hopping motor constant speed timer value (I/O setting value) [unit: HEX]
FRM : [***] = Frame thermistor read-out AD value [unit: HEX]
(XXX) = Frame temperature [unit:
DB:k**y**m**c**
DB : Develop voltage setting table ID number [unit: HEX]