Hearth; Framing & Finishing; Final Finishing; Gas Specifications - Majestic 33LDVT Installation Instructions And Homeowner's Manual

Ldvt series direct vent gas fireplace
Table of Contents

Advertisement

A hearth is not mandatory but is recommended for
aesthetic purposes. We recommend a noncombustible
hearth which projects out 12" (305mm) or more from
the front of the fireplace.
Cold climate installation recommendation:
When installing this unit against a non-
insulated exterior wall or chase, it is
mandatory that the outer walls be insulated
to conform to applicable insulation codes.
Framing and Finishing
Check fireplace to make sure it is levelled
and properly positioned.
To mount the appliance:
1. Choose the location.
2. This unit comes with four (4) flanges pre-mounted
on both sides of the fireplace to allow two different
drywall thicknesses to be used. Flange "A" is for 1/2"
drywall while flange "B" is for 5/8" drywall.
3. Bend the desired flanges out 90° on both sides of
the fireplace. Slide the fireplace into the framed
opening until the flanges contact the front surfaces
of the framing. Level the unit and secure it firmly in
place.
Flange Location for Desired Drywall Depth
Flange
Drywall
Position
Depth
A
1/2" / 13 mm
B
5/8" / 16 mm
A
B
Fig . 4 Nailing flanges.

Final Finishing

Noncombustible materials such as brick or tile may be
extended over the edges of the face of the appliance.
DO NOT cover any vent or grille panels.
If a Trim Kit is going to be installed on the fireplace, the
brick or tile will have to be installed flush with the edges
of the appliance.
10007852

Hearth

FP1546
LDVT nailing flanges
1/05
LDVT Series Direct Vent GaS Fireplace
Model
33LDVTRN
33LDVTRP
33LDVTEN
33LDVTEP
33LDVTIN
33LDVTIP*
36LDVTRN
36LDVTRP
36LDVTEN
36LDVTEP
36LDVTIN
36LDVTIP*
39LDVTRN
39LDVTRP
39LDVTEN
39LDVTEP
39LDVTIN
39LDVTIP*
43LDVTRN
43LDVTRP
43LDVTEN
43LDVTEP
*Using conversion kit
Model
33LDV
36/39/43LDV
33/36/39/43LDV

Gas Inlet and Manifold Pressures

Inlet Minimum
Inlet Maximum
FP1546
Manifold Pressure
Gas Specifications
Gas
Fuel
Control
Nat
Millivolt
Prop
Millivolt
Nat
24V Hi/Lo
Prop*
24V Hi/Lo
Nat.
6V DC Hi/Lo
Prop.* 6V DC Hi/Lo
Nat
Millivolt
Prop
Millivolt
Nat
24V Hi/Lo
Prop*
24V Hi/Lo
Nat.
6V DC Hi/Lo
Prop.* 6V DC Hi/Lo
Nat
Millivolt
Prop*
Millivolt
Nat
24V Hi/Lo
Prop*
24V Hi/Lo
Nat.
6V DC Hi/Lo
Prop.* 6V DC Hi/Lo
Nat
Millivolt
Prop*
Millivolt
Nat
24V Hi/Lo
Prop*
24V Hi/Lo

Air Shutter Adjustment

Gas Type Air Shutter Opening
Natural
Natural
Hole Half Closed
Propane
Natural
5.5" w.c.
14.0" w.c.
3.5" w.c.
Max.
Min.
Input
Input
BTU/h
BTU/h
16,000
11,200
16,000
12,000
16,000
11,200
16,000
12,000
16,000
11,200
16,000
12,000
19,500
13,650
19,500
14,625
19,500
13,650
19,500
14,625
19,500
13,650
19,500
14,625
23,000
16,100
22,500
16,875
23,000
16,100
22,500
16,875
23,000
16,100
23,000
16,875
26,000
18,200
24,000
18,000
26,000
18,200
24,000
18,000
3/16" Open
Top & Bottom
Fully Open
LP (Propane)
11.0" w.c.
14.0" w.c.
10.0" w.c.
7