Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
HIDDEN BAKE ELEMENT
Refer to page 4-38 for the procedure for ac-
cessing the hidden bake element.
NOTE: The hidden bake element will be tested
at the appliance manager board (see page
4-18).
1.
Unplug oven or disconnect power.
2.
Set the ohmmeter to the R x 1 scale.
3.
Touch the ohmmeter test leads to wire con-
nectors T3-3 (RD) and T1-1 (RD). The meter
should indicate between 26 and 30 Ω.
WARNING
Electrical Shock Hazard
1 2 3 4 5
Lower Oven
Appliance Manager
5-15
T1
T3