Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
MICROWAVE LIGHT TRANSFORMER
Refer to page 4-4 for the procedure for access-
ing the microwave light transformer.
1.
Unplug oven or disconnect power.
2.
Disconnect one of the wires from the LINE
(primary) and one from the LOAD (second-
ary) terminals.
3.
Set the ohmmeter to the R x 1 scale.
4.
Touch the ohmmeter test leads to the LINE
terminals. The meter should indicate ap-
proximately 45 Ω.
5.
Touch the ohmmeter test leads to the LOAD
terminals. The meter should indicate ap-
proximately 0.6 Ω.
WARNING
Electrical Shock Hazard
CONVECTION THERMOACTUATOR
Refer to page 4-5 for the procedure for access-
ing the convection thermoactuator.
1.
Unplug oven or disconnect power.
2.
Disconnect one of the wires from the ther-
moactuator terminals.
3.
Set the ohmmeter to the R x 1 scale.
4.
Touch the ohmmeter test leads to the ther-
moactuator terminals. The meter should
indicate approximately 2.3 Ω.
5-2