"Duzy" Series Vented Gas Log Sets
MAkE SURE YOU HAVE RECEIVED ALL
PARTS:
Check your packing list to verify that all listed parts have
been received. You should have the following:
BURNER - GRATE ASSEMBLY 24/18, 30
•
Burner and Grate Weldment Assembly
•
Lava Rocks (2)
•
Glowing Embers (Rock Wool)
•
Damper Clamp
•
Installation /Operating Instructions
•
Masonry Screws (2)
•
3/8" Aluminum tube with 3/8" 90° elbow, 1/2" to 3/8"
tube fitting
CERAMIC FIBER OR REFRACTORY CE-
MENT LOGS 24/18, 30
•
Individual Logs
•
Installation Instructions
Carefully inspect the contents for shipping damage. If any
parts are missing or damaged, immediately inform the
dealer from whom you purchased the appliance. Do not
attempt to install any part of the appliance unless you
have all parts in good condition.
ITEMS REQUIRED FOR INSTALLATION
Ensure that the following items are available before pro-
ceeding with installation:
•
External regulator (for propane/L.P.G. only)
•
Manual shutoff valve
•
Piping which complies with local codes
•
Pipe wrench
•
Tee joint
•
Pipe sealant approved for use with propane/L.P.G.
(Resistant to sulfur compounds)
•
Drill with masonry bit (for mounting to the floor)
•
Handle the gas log burner assembly by
the grate only. Do not pick the unit up by
the burner.
•
Gloves are recommended when handling
ceramic fiber logs to prevent skin irritation
from loose fibers. Logs are fragile —
handle with care.
4
GETTING STARTED - FEATURES & SPECIFICATIONS
GAS PRESSURES
Inlet Minimum
Inlet Maximum
Regulator Pressure
*NOTE: An external regulator is required to reduce supply pres-
sure to a maximum of 13" w.c.
GAS SPECIFICATIONS
Model
VDY24/18NMP
VDY24/18PMP
VDY24/18NVP
VDY24/18PVP
VDY30NMP
VDY30PMP
VDY30NVP
VDY30PVP
IGNITION CONTROLS
Piezo ignitor allows ignition of the pilot without the use of
matches or batteries.
Manual control with pilot has three (3) positions:
OFF - All gas to the gas logs is shut off at the valve.
IGN - Valve position to light/maintain a standing pilot.
ON - Valve position to light/maintain the gas burner.
Millivolt control with pilot has three (3) positions:
OFF - All gas to the gas logs is shut off at the valve.
IGN - Valve position to light/maintain a standing pilot.
ON - Valve position to light/maintain the gas burner.
Natural
*Propane (LP)
6.0" w.c.
10.5" w.c.
4.0" w.c.
Fuel
Control
Nat. Manual (thermocouple)
LP
Manual (thermocouple)
Nat. Millivolt (thermopile)
LP
Millivolt (thermopile)
Nat. Manual (thermocouple)
LP
Manual (thermocouple)
Nat. Millivolt (thermopile)
LP
Millivolt (thermopile)
11.0" w.c.
13.0" w.c.
10.0" w.c.
Gas Rate
Min. Input
BTU/h
50,000
50,000
50,000
50,000
65,000
65,000
65,000
65,000
32D1999