Millivolt Control Lighting Instructions; To Turn Off Gas To Heater; Match Lighting Instructions - MHSC Duzy VDY24 Installation And Operating Instructions Manual

Duzy series vented gas log set
Table of Contents

Advertisement

OPERATING INSTRUCTIONS

MILLIVOLT CONTROL LIGHTING INSTRUCTIONS

1. STOP! Read the safety information label.
2. Make sure the manual shutoff valve is fully open.
3. This gas log set is equipped with an ignition device (piezo) which automatically lights the pilot. If piezo
ignitor does not light the pilot, see instructions for Match Lighting below.
4. Turn gas control knob clockwise
5. Wait (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas,
STOP! Follow "B" in the safety information label. If you don't smell gas, go to next step.
6. From "OFF" position, turn the gas control knob counterclockwise
knob for 5 seconds.
7. With the control knob pushed in, push in and release the piezo ignitor button to light the pilot.
8. Continue pushing the control knob in for a further 60 seconds to prevent the flame detector from shut-
ting off the gas while the probe is warming up. Release the control knob.
9. Turn gas control knob counterclockwise
10.After the pilot has been lit for one minute, the burners can be turned on. Turn the ON/OFF switch to
"ON" position.
11.If the gas logs will not operate, follow the instruc-
tions To Turn Off Gas To Heater and call your
service technician or gas supplier.
Millivolt Pilot
FP2859
millivolt pilot flame
1. Turn control knob clockwise
2. If applicable: Turn ON/OFF switch to "OFF" position.
3. If applicable: Turn off all electric power to the heater.
1. Remove any items necessary for easy access to the pilot (for example: logs, screens, etc.).
2. Follow appropriate lighting instructions found previously. Instead of pushing and releasing the piezo
button, light a match and hold the flame to the end of the pilot and ignite the pilot.
3. After control knob has been released and pilot stays lit, re-install any items that were removed for
pilot access.
4. Call a qualified service technician for repair or replacement of the piezo ignitor.
32D1999
to the "OFF" position, and turn ON/OFF switch to "OFF" position.

TO TURN OFF GAS TO HEATER

to "OFF" position to completely shut off the heater.

MATCH LIGHTING INSTRUCTIONS

to the "ON" position.
Wait 30 seconds before readjusting the
heater when the control knob has been
turned down to a lower setting.
Control knob
FP2861
millivolt control knob
"Duzy" Series Vented Gas Log Sets
to "IGN" position. Push in control
FP2862
On/Off Switch
on off switch
25

Hide quick links:

Advertisement

Table of Contents
loading