CLEANING AND SERVICING

Turn off gas logs and allow to cool before
cleaning. Disconnect electrical power if
applicable before cleaning or servicing.
Remove logs, handling carefully by holding gently at each end. Gloves are recommended to
prevent skin irritation from ceramic fibers. If skin becomes irritated, wash gently with soap and
water. See manual for correct log placement.
PERIODIC CLEANING - SEE PARTS DIAGRAM FOR LOCATION OF ITEMS DISCUSSED
BELOW.
Do not use cleaning fluid to clean logs or any part of gas logs.
Logs - brush with soft bristle brush or vacuum with brush attachment.
Vacuum loose particles and dust from the control and grate weldment.
Inspect and clean burner air intake holes. Remove lint or particles with vacuum or brush.
Failure to keep air intake holes clean will result in sooting and poor combustion.
If embers (rock wool) have turned a rust color and become brittle, remove old embers
(rock wool) from log set. Replace with new rock wool. Rock wool can be purchased from
your local dealer. See log placement section for placement of embers.
ANNUAL CLEANING/INSPECTION - SEE PARTS DIAGRAM FOR LOCATION OF ITEMS
DISCUSSED BELOW.
Inspect and clean all burner ports.
Verify burner and pilot flame pattern and log placement for proper operation.
Verify smooth and responsive ignition of burner.
Inspect and clean chimney.
Inspect and clean burner air intake holes. Remove lint or particles with vacuum or brush.
Failure to keep air intake holes clean will result in sooting and poor combustion.