9. Tone Dialling simulators (Tone Pads)
For the acknowledgement procedure the SD1 "looks" for any tone between 600Hz and
1400Hz. This is supplied most reliably by the [8] button used for MF dialling although other
buttons may work if pressed accidentally.
If the recipients phone cannot produce a suitable tone then a Tone Dialling Simulator (Tone
Pad) must be used. These are available from many high street electrical stores and also from
specialist suppliers such as RS Components (stock code 252-841) and Maplin Electronics
(stock code CK25C).
10. Trouble-Shooting Guide
Problem
The unit will not dial out.
Cause
Number incorrectly dialled
Action
Check the telephone number you are calling has been entered correctly.
Cause
The SD1 is not compatible with PABXs that require a pause or wait for secondary
dial tone.
Action
Program the unit to pulse dial (see Operating Instructions). If this does not solve
the problem the dialler must be connected to a direct telephone line.
Cause
Incorrect telephone line connections.
Action
Check the connections to the telephone line (see section 7).
Problem
When the unit calls the recipient they can't acknowledge the unit by pressing
the number [8] button.
Cause
Incorrect acknowledgement procedure.
Action
Instruct the recipient in the correct procedure (see Operating Instructions).
Cause
Incorrectly connected to the telephone socket.
Action
Check that all three connections are correctly connected (see section 7).
Cause
Incompatible telephone.
Action
Call the recipient and ask them to press the number [8] button on their telephone
for 1 second. If you hear anything other than a 1 second tone, their telephone
is not capable of acknowledging the SD1 (see section 9).
Problem
The recipient can't acknowledge the unit with a mobile telephone.
Cause
Weak reception or incompatible telephone.
Action
Mobile telephones will only work correctly if they are used in an area where the
reception is good. Also check their tone duration (see section 9).
Problem
The SD1 will not trigger from the alarm panel.
Cause
Incorrect polarity setting.
Action
Check the jumper-link is set to the correct position (see section 5).
Cause
Incorrect trigger voltage.
Action
Measure trigger voltage and check connections ( see section 6).