Figure 1. 1/8 Din Panel Cutout Dimensions; Figure 2. Panel Mounting Details - Omega DP6060 User Manual

Dual-input process meter
Table of Contents

Advertisement

DP6060 Dual-Input Process Meter
Panel thickness: 0.04" - 0.25" (1.0 mm - 6.4 mm).
Recommended minimum panel thickness to maintain Type 4X
rating: 0.06" (1.5 mm) steel panel, 0.16" (4.1 mm) plastic panel.
Remove the two mounting brackets provided with the meter (back-off the two
screws so that there is ¼" (6.4 mm) or less through the bracket. Slide the
bracket toward the front of the case and remove).
Insert meter into the panel cutout.
Install mounting brackets and tighten the screws against the panel. To
achieve a proper seal, tighten the mounting bracket screws evenly until
meter is snug to the panel along its short side. DO NOT OVER TIGHTEN,
as the rear of the panel may be damaged.

Figure 1. 1/8 DIN Panel Cutout Dimensions

Square Corners to 0.060"
(1.5mm) Max Radius
B
1.772"
(45mm)
Tolerances:
A: +0.032 (+0.8mm)
-0.000 (-0.0mm)
B: +0.024 (+0.6mm)
-0.000 (-0.0mm)
Gasket
Panel
Mounting
Bracket

Figure 2. Panel Mounting Details

A
3.622" (92 mm)
Panel Cutout
to DIN 43700
Removable
Connectors
Mounting
Screw
18
Instruction Manual