Vertical Into Existing Class A Chimney; Through The Wall & Vertical - Exterior; Vertical - Interior - Typical Installation - Quadra-Fire MTV-E2-CSB Installation Manual

Mt. vernon e2 series
Hide thumbs Also See for MTV-E2-CSB:
Table of Contents

Advertisement

B. Vertical into Existing Class A Chimney
Flashing
Firestop
Ceiling Support
6 in
[152mm]
Min
Non-combustible Hearth Pad
Figure 15.1
C. Through The Wall & Vertical - Exterior
2 in [51mm] min
6 in
[152mm]
Min
Figure 15.2
October 28, 2014
Rain Cap
12 in. [305mm] Min
6 in. [152mm] Class A
Chimney Connector
Adapter
3 in [76mm] Min
3 to 6 in [76 to 152mm]
Offset Adapter
3 to 3 in
[76-76mm]
Top Vent Kit
Clean-out Cover
Rain
Cap
12 in
Flashing
[305 mm]
Minimum
Support
Bracket
every 60 in
[1524mm]
Wall Thimble
Tee
Clean-out
Cover
Non-combustible Hearth Pad
We recommend a minimum of 60 inches
(1524mm) vertical, however above the eave
is preferred.
All three installations are approved for mobile
home installations. Must use 3 or 4 inch (76
to 102mm) "L" or "PL" Listed pellet venting or
Listed double wall pipe and Quadra-Fire Outside
Air Kit in mobile homes. Single wall pipe is
approved for residential installations only.
*NOTE: Clearance to combustibles are for
standard pellet pipe. If pellet pipe manufacturer
allows reduced clearances to their pipe, reduced
clearances are allowed.
A chimney connector shall not pass through
an attic or roof space, closet or similar
concealed space, or a fl oor or ceiling.
D. Vertical - Interior - Typical Installation
Firestop
6 in
[152mm]
Min
Figure 15.3
7080-131D
MT VERNON E2
NOTE:
Rain
Cap
12 in
[305 mm]
Flashing
Minimum
3 in [76mm] Min
3 to 3 in
[76 to 76mm]
Top Vent Kit
Clean-out Cover
Non-combustible Hearth Pad
15

Advertisement

Table of Contents
loading

Table of Contents