INSTALLER: Leave this manual with party responsible for use and operation.
OWNER: Retain this manual for future reference.
MT. VERNON PELLET STOVE
ADVANCED ENERGY (AE)
Model(s):
MTVERNON-AE-CSB
MTVERNON-AE-MBK
MTVERNON-AE-PBK
MTVERNON-AE-PDB
MTVERNON-AE-PFT
MTVERNON-AE-PMH
CAUTION
Tested and approved for wood pellets, shelled fi eld
corn, wheat and black oil sunfl ower seeds. Burning of
any other type of fuel voids your warranty.
CAUTION
Check building codes prior to installation.
• Installation MUST comply with local, regional, state and na-
tional codes and regulations.
• Consult local building, fi re offi cials or authorities having juris-
diction about restrictions, installation inspection, and permits.
1
Installation Manual
Installation & Appliance Set-Up
NOTICE: DO NOT DISCARD THIS MANUAL
Tested and
Portland
O-T L
Listed by
Oregon USA
C
US
OMNI-Test Laboratories, Inc.
061-S-68-6
If the information in these instruc-
tions is not followed exactly, a
fi re may result causing property
damage, personal injury, or death.
• Do not store or use gasoline or other fl am-
mable vapors and liquids in the vicinity of
this or any other appliance.
• Do not overfi re - If heater or chimney con-
nector glows, you are overfi ring. Overfi ring
will void your warranty.
• Comply with all minimum clearances to
combustibles as specifi ed. Failure to
comply may cause house fi re.
Hot glass will cause burns.
Do not touch glass until it is cooled
NEVER allow children to touch glass
Keep children away
CAREFULLY SUPERVISE children in same room as
fi replace.
Alert children and adults to hazards of high temperatures
High temperatures may ignite clothing or other
fl ammable materials.
Keep clothing, furniture, draperies and other fl ammable
materials away.
To obtain a French translation of this manual, please contact
your dealer or visit www.quadrafi re.com
Pour obtenir une traduction française de ce manuel, s'il vous
plaît contacter votre revendeur ou visitez www.quadrafi re.com
7034-277E
WARNING
WARNING
HOT SURFACES!
Glass and other surfaces are hot
during operation AND cool down.
NOTE
May 5, 2015

Advertisement

Table of Contents
loading

Summary of Contents for Quadra-Fire MTVERNON-AE-CSB

  • Page 1 fi re may result causing property ADVANCED ENERGY (AE) damage, personal injury, or death. Model(s): • Do not store or use gasoline or other fl am- MTVERNON-AE-CSB mable vapors and liquids in the vicinity of MTVERNON-AE-MBK this or any other appliance. MTVERNON-AE-PBK •...
  • Page 2: Table Of Contents

    MT. VERNON AE Safety Alert Key: • DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury. • WARNING! Indicates a hazardous situation which, if not avoided may result in death or serious injury. •...
  • Page 3: Important Safety Information

    ASTM E1509-04, ULC S627-00, (UM) 84-HUD and ULC/ORD- C-1482. WARNING The Quadra-Fire Mt. Vernon AE Pellet Heater meets the U.S. Environmental Protection Agency’s emission limits for pellet Fire Risk. heaters sold after May 15, 2015.
  • Page 4: Getting Started

    MT. VERNON AE Install Guide Getting Started A. Design, Installation & Location Considerations Since pellet exhaust can contain ash, soot or sparks, you must consider the location of: 1. Appliance Location • Windows NOTICE: Check building codes prior to installation. •...
  • Page 5: Thermostat Wall Control Location

    MT. VERNON AE B. Thermostat Wall Control Location D. Inspect Appliance and Components The thermostat wall control’s location will have some affect • Open the appliance and remove all the parts and articles on the appliance’s operation. packed inside the Component Pack. Inspect all the parts and glass for shipping damage.
  • Page 6: Install Checklist

    Location of Fireplace: Installer: Dealer/ Distributor Phone #: Serial #: Model (circle one): MTVERNON-AE-CSB MTVERNON-AE-MBK MTVERNON-AE-PBK MTVERNON-AE-PDB MTVERNON-AE-PFT MTVERNON-AE-PMH WARNING! Risk of Fire or Explosion! Failure to install fi replace according to these instructions can lead to a fi re or explosion.
  • Page 7: Dimensions And Clearances

    MT. VERNON AE Dimensions and Clearances A. Appliance Dimensions 14-1/16 in. 5-13/16 in. (357mm) (147mm) 3-13/16 in. (97mm) 2-9/16 in. (65mm) 31-1/6 in. (788mm) 29-3/6 in. (741mm) Figure 7.1 - Top View with Top Vent Adapter and 3 to 6 Figure 7.2 - Side View with Top Vent Adapter and 3 to in (76-152mm) Adapter 6 in (76-152mm) Offset Adapter.
  • Page 8: Clearances To Combustibles (Ul And Ulc)

    MT. VERNON AE C. Hearth Pad Requirements (UL and ULC) B. Clearances to Combustibles (UL and ULC) Use a non-combustible fl oor protector, extending beneath appliance and to the front, sides and rear as indicated. Mea- sure front distance “M” from the surface of the glass door. Straight Back Against Wall Inches Millimeters...
  • Page 9: Vent Information

    MT. VERNON AE Vent Information A. Venting Termination Minimum Requirements Electrical Service Inside Corner FIXED FIXED OPEN CLOSED CLOSED OPEN J or K Figure 9.1 Termination Cap Air Supply Inlet Restricted Area Gas Meter All minimum clearances are listed with an Outside Air Kit (OAK) installed, unless otherwise noted in table below. 12 in.
  • Page 10: Avoiding Smoke And Odors

    MT. VERNON AE B. Avoiding Smoke and Odors Vent Confi gurations To reduce probability of reverse drafting during shut-down Negative Pressure, Shut-Down and Electrical Power conditions Hearth & Home Technologies strongly recom- Failure mends: To reduce the probability of back-drafting or burn-back in •...
  • Page 11: Negative Pressure

    6 inch (76-152mm) Top Vent Offset Adapter, use Listed • Attic mounted duct work and air handler joints and seams double wall fl ue connector. A Quadra-Fire Outside Air Kit taped or sealed must be used with manufactured home installations.
  • Page 12: Equivalent Feet Of Pipe

    MT. VERNON AE F. Equivalent Feet of Pipe WARNING The table below can help you calculate the equivalent feet Vent surfaces get HOT, can cause burns if of pipe which is a method used to determine pellet vent size. touched. Non-combustible shielding or guards Figure 12.1 may be required.
  • Page 13: Venting Systems

    MT. VERNON AE Venting Systems A. Alcove Figure 13.1 Minimum* Maximum Inches Millimeters Inches Millimeters Height 1092 Width 1016 Depth To Side Wall *All minimums listed are to a combustible surface. NOTE: • Illustrations refl ect typical installations and are FOR DESIGN PURPOSES ONLY.
  • Page 14: Through The Wall

    Must use 3 or 4 inch (76-102mm) “L” or “PL” Listed bustible construction is desired, the installation shall conform to CAN/CSA-B365 pellet venting or Listed double wall pipe and a Quadra-Fire Outside Air Kit in mobile homes. 2 in.
  • Page 15: Vertical Into Existing Class A Chimney

    Must use 3 or 4 inch (76 Flashing to 102mm) “L” or “PL” Listed pellet venting or 12 in. (305mm) Minimum Listed double wall pipe and Quadra-Fire Outside Air Kit in mobile homes. Single wall pipe is approved for residential installations only. Firestop 6 in.
  • Page 16: Masonry

    MT. VERNON AE WARNING Fire Risk. Inspection of Chimney: • Masonry chimney must be in good condition. • Meets minimum standard of NFPA 211 • Factory-built chimney must be a minimum 6 inch (152mm) UL103 HT. F. Masonry Fireclay flue Concrete Cap liner with airspace Flashing...
  • Page 17: Appliance Set-Up

    MT. VERNON AE Appliance Set-Up A. Leg Leveling System B. Outside Air Kit Instructions 1. Thread Allen bolts through nuts until fl ush. Figure 17.1. The Allen bolts and nuts are included in the component pack CAUTION inside the appliance fi rebox. Never draw outside combustion air from: 2.
  • Page 18: Top Vent Adapter Installation

    MT. VERNON AE C. Top Vent Adapter Installation 3 to 3 inch (76-76mm) Top Vent Adapter 3 to 6 inch (76-152mm) Top Vent Offset Adapter Installing the Top Vent Adapter Put a layer of high temperature silicone on the 3 inch (76mm) exhaust outlet.
  • Page 19: Optional Log Set Placement Instructions

    MT. VERNON AE E. Optional Log Set Placement Instructions 2 PIECE LOG SET INSTALLATION 1. Place the left log as shown. There are 2 indentations in the bottom of the log to fi t over the screw heads in the fi...
  • Page 20: Wall Control Thermostat Installation

    MT. VERNON AE F. Wall Control Thermostat Installation When mounting the wall control thermostat on the wall, be sure to follow your thermostat wall control’s installation instructions carefully. Wall Control Thermostat Wires Attach to Center 3 Screws NOTE: The wall control thermostat should be mount- ed on an inside wall and not in direct line with the Green White appliance convection air.
  • Page 21: Mobile Home Installation

    MT. VERNON AE Mobile Home Installation CAUTION You must use a Quadra-Fire Outside Air Kit for installation in a mobile home. THE STRUCTURAL INTEGRITY OF THE MOBILE HOME FLOOR, WALL AND CEILING/ROOF MUST BE An outside air inlet must be provided for the combustion...
  • Page 22: Accessory List

    MT. VERNON AE Accessory List ACCESSORIES 12 Volt Power Cord 12VCORD-AE Collar, Offset, Top Vent 812-3570 Damper, 3 Inch - Tall Vertical Installs Only PEL-DAMP3 Damper, 4 Inch - Tall Vertical Installs Only PEL-DAMP4 Firescreen No Longer Available SCR-7005 Log Set, (Sold as Set only) 2 Pc LOGS-60-AE-B Outside Air Kit...
  • Page 23 MT. VERNON AE May 5, 2015 7034-277E...
  • Page 24 Hearth & Home Technologies 1445 North Highway Colville, WA 99114 Division of HNI INDUSTRIES Please contact your Quadra-Fire dealer with any questions or concerns. For the number of your nearest Quadra-Fire dealer log onto www.quadrafi re.com CAUTION DO NOT DISCARD THIS MANUAL...