Installation; System Layout; Condenser Unit Installation - Follett MC825 Series Installation, Operation And Service Manual

Icemaker with remote condensing unit
Table of Contents

Advertisement

Installation

Icemaker performance is very sensitive to the quality of installation. To ensure proper performance, ease of
service and warranty coverage, it is critical that you follow the requirements detailed in this manual. If you cannot
meet these requirements or have questions, call our technical service group immediately at (800) 523-9361 or
(610) 252-7301.

System layout

60"
(1524mm)
Clearances
Installation Specifications
Outdoor ambient temperature range: – 20°F – 130°F
( – 29°C – 54.4°C).
Indoor ambient temperature range: 50°F – 90°F
(10°C – 32°C).
Installations with condenser unit above indoor unit
require a suction line S-trap at the bottom of the rise.
Installation with condenser unit elevations above 20 ft (6.1m)
require an additional S-trap at the midpoint of the rise.
Maximum line rise must not exceed 35 ft (10.7m).
Maximum line set length must not exceed 100 feet (30.5m).
Max line drop must not exceed 15 ft (4.6m).
Note: The service loop is not included when calculating the
length, rise or drop of the tubing run.
Water pressure 10 psi – 70 psi.
Water temperature 50°F – 90°F (10°C – 32°C).
Install condenser unit
Mount condenser unit
1. Level unit.
2. Securely attach base of unit using holes found in
base plate.
Electrical connection
Refer to wiring schematic located in condenser unit
electrical box.
Note: Electric disconnects required within 10 ft (3m)
for all hard-wired connections.
Note: Install in accordance with NEC and local
electrical codes.
Condenser unit
8" (204mm)
Discharge air
8" (204mm)
24"
(610mm)
Air flow
additional
S - trap
install
required
5
Evaporator
12" (305mm)
6"
6"
(153mm)
(153mm)
Refrigeration line
elevation specifications
Condenser unit
Maximum line
height
35 ft
(10.7m)
20 ft+
(6.1m)
Condenser unit
S - trap install
required
3 ft+
(.9m)
Evaporator unit level
Condenser unit
Maximum line
drop
-15 ft
(-4.6m)

Advertisement