Installation - Follett Maestro Chewblet MSC44SC Installation, Operation And Service Manual

Ice machine and top kit for remcor/cornelius countertop ice and beverage dispensers
Table of Contents

Advertisement

Installation

1.
Install Cornelius ice dispenser according to
manufacturer's specifi cations.
Note: We recommend that the dispenser back
be mounted at least 1" (26mm) from wall to allow
water, drain and electric lines from top-mount ice
machines to be concealed behind dispenser.
2. Disconnect power to dispenser.
3. Remove front panel/merchandiser from the
dispenser.
4. Adjust the agitation timer located on Cornelius PC
board
to 1 second on – 1 hour off (Fig. 1).
5. Install supplied nugget
ice diverter at dispenser
opening.
a) Disassemble
chute assembly
and discard gate
restrictor (Fig. 2.1).
b) Reassemble with
supplied ice
diverter as shown
(Fig. 2.2).
6. Reinstall front panel.
6
Maestro 400 Series Top Kit for Remcor/Cornelius
Fig. 2
2
ice diverter
(supplied)
ice chute
flat washer
10-32 nut
Fig. 1
agitation
timer
ON
OFF
storage hopper
gate
mounting
plate
apply RTV to this
surface to seal to
mounting plate
gasket
1
gate
restrictor
plate
flange extends
into storage
hopper through
gate opening
hopper gate

Advertisement