Installation; Location; Leveling; Utility Connections - Follett Ice Pro EDB650 Installation, Operation And Service Manual

Automatic ice bagging and dispensing system
Hide thumbs Also See for Ice Pro EDB650:
Table of Contents

Advertisement

Installation

Location

A minimum of 12" (305 mm) to the right of the unit must be available
for service clearance (see dimensions and clearances - page 5).
Allow access to front of unit for bagging operation and dispensing.

Leveling

Leveling the unit is important for the proper operation of any
top mounted icemaker. The dispenser is shipped with the legs in the
fully retracted position. Each leg may be adjusted independently by
turning clockwise to lower the leg or counterclockwise to raise the
leg. Do not remove legs; interference will occur with the bag stand
and dispense chute.

Utility connections

Bin drain
Drain connection is made to the 1" FPT PVC fitting (Fig. 1). Allow a
minimum of
1/4" per foot (1 cm per 46 cm run) slope on drain line run.
Insulate the entire run length to prevent condensation from forming on
outside of drain line.
Note: Avoid excessive tightening force when connecting to this fitting.
Note: Do not apply excessive heat if any sweating of fittings is
necessary. Heat conduction through metal may melt threads in
plastic drain.
Drain pan
The drain pan on the bag stand may be drilled out and plumbed
if desired. Use an 11/16" drill bit, a 3/4" FPT elbow and PVC glue.
Plumb with flexible tubing to allow for height adjustment.
Electrical
Electrical connections to be in accordance with local and national
electrical codes. Each dispenser and icemaker require separate
circuits. Equipment ground required.
Note: If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified persons in order to
avoid a safety hazard.
DB650
220V, 60Hz, 1 phase. Max. fuse – 5 amps, 15 amp circuit.
Provide NEMA 6-15 receptacle within 7' (2.1 m) of right rear corner.
Cord and plug provided.
EDB650
230V, 50Hz, 1 phase. Max. fuse – 5 amps, 15 amp circuit, max
power - 3450 watts. Provide means of connection within 7' (2.1 m) of
right rear corner. Cord provided without plug.
Fig. 1
8.25"
(210 mm)
6
Bottom view
drain
13.5"
(343 mm)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ice pro db650Ice pro db650saIce pro edb650sa

Table of Contents