Follett MC825 Series Installation, Operation And Service Manual page 11

Icemaker with remote condensing unit
Table of Contents

Advertisement

12. Fill reservoir (Fig. 7.2) with Solution A.
13. Turn bin signal switch (Fig. 8.1) on electrical box of icemaker ON (to
allow gearmotor to run).
14. Wait 10 minutes. Turn compressor switch ON (Fig. 8.3).
15. Keep reservoir (Fig. 7.2) full of Solution A while making ice for 20
minutes.
16. Turn compressor switch OFF (Fig. 8.3).
17. Rinse ice compression nozzles (Fig. 9.1) with water and reinstall.
18. Drain any remaining sanitizing solution from reservoir through float/
evaporator drain line (Fig. 7.1).
19. Fill reservoir (Fig. 7.2) with 120°F (49°C) water. Empty water through
float/evaporator drain line (Fig. 7.1). Repeat 3 times.
20. Turn ON water to icemaker.
21. Turn compressor switch ON (Fig. 9.3).
22. Replace reservoir cover and any panels removed to clean icemaker.
23. Make ice for 15 minutes to flush any remaining solution from system
(remote icemakers with long transport tubes may take longer to flush
out). Discard this and all ice made during sanitizing.
24. Replace float reservoir lid and evaporator unit panels.
Fig. 10
11
1
3
4
2

Advertisement

Table of Contents
loading

Table of Contents