Connector
Pin
YC11
25
BCACNT
Connected to
26
BMACNT
high voltage
PWB
27
BYACNT
28
HVCLKK
29
BCSCNT
30
HVCLKM
31
GND
32
GND
YC13
1
MOTREV
(GND)
Connected to
2
MOTRDYN
drum motor
3
SPEEDSEL
4
MOTCLK
5
MOTEN
6
GND
7
+24V3
YC14
1
+24V3
Connected to
2
GND
developing
3
DLPMOTREN
motor
4
DLPMOTCLK
5
DLPMOT
RDYN
6
MOTREV
YC15
1
IMAMOT
RDYN
Connected to
2
IMAMOTCLK
fuser motor
3
IMAMOTREN
4
GND
5
+24V3
YC16
1
+3.3V2_LED1
Connected to
2
GND
MP paper
3
MPFPAP
sensor
Signal
I/O
O
PWM
O
PWM
O
PWM
O
0/3.3 V DC (pulse) Developing bias clock signal (Black)
O
PWM
O
0/3.3 V DC (pulse) Developing bias clock signal (Magenta)
-
-
-
-
-
-
I
0/3.3 V DC
O
0/3.3 V DC
O
0/3.3 V DC (pulse) DRM clock signal
O
0/3.3 V DC
-
-
O
24 V DC
O
24 V DC
-
-
O
0/3.3 V DC
O
0/3.3 V DC (pulse) DEVM clock signal
I
0/3.3 V DC
O
0/3.3 V DC
I
0/3.3 V DC
O
0/3.3 V DC (pulse) FUM clock signal
O
0/3.3 V DC
-
-
O
24 V DC
O
3.3 V DC
-
-
I
0/3.3 V DC
Voltage
Developing AC bias control voltage
(Cyan)
Developing AC bias control voltage
(Magenta)
Developing AC bias control voltage
(Yellow)
Developing sleeve roller bias control
voltage (Cyan)
Ground
Ground
Ground
DRM ready signal
DRM speed selection signal
DRM: On/Off
Ground
24 V DC power to DRM
24 V DC power to DEVM
Ground
DEVM: On/Off
DEVM ready signal
DEVM drive switch signal
FUM ready signal
FUM: On/Off
Ground
24 V DC power to FUM
3.3 V DC power to MPPS
Ground
MPPS: On/Off
2-3-7
2KT/2KV
Description