4. Remove the screw and two terminals
and then remove the power source
inlet.
5. Check or replace the power source inlet
and refit all the removed parts.
*: Before mounting the AC inlet on the main
unit, twist the wires 5 to 7 turns.
Terminal
Terminal
Figure 1-5-75
Figure 1-5-76
1-5-50
2KT/2KV
Power source inlet
Screw
Power source inlet
Five to seven times twist