Span, Position And Trace Functions To Adjust The Waveform Display - GRAPHTEC midi LOGGER GL220 Quick Start Manual

Hide thumbs Also See for midi LOGGER GL220:
Table of Contents

Advertisement

Span, Position and Trace Functions to Adjust the Waveform Display

These functions enable to make adjustments in order to view individual channels
more easily, and to delete waveforms that is not required to view in display.
Points to
The span, position and trace operations can be performed while the GL220
Remember
is in the Free Running status, while it capturing data, and while it is replaying
data. The changes are applied to the displayed data only, the change is not
affected to the captured data.
1.How to Make a Span setting
The Span parameter is used to adjust the amplitude of the input waveform.
This setting is made in the aforementioned Free Running status.
 (1) Set the displayed span for CH 1 to 100ºC.
 (2) Press the SPAN/POSITION/TRACE key to select the SPAN mode.
 (3) Use the
Use the
Use the
and
and
and
 (4) Use the
and
When this setting has been changed, the waveform screen scale will be set to "+100.0 to +0.0".
When this setting has been changed, the waveform screen scale will be set to "+100.0 to +0.0".
2.How to make a Position setting
The Position parameter is used to adjust the position of displayed waveform that is set by
the upper and lower values.
 (1) Press the SPAN/POSITION/TRACE key to select the POSITION mode.
 (2) Use the
and
keys to make CH 1 active (enlarged display).
 (3) Use the
and
keys to set the Position value to "+80ºC to -20ºC".
 When this setting has been changed, the waveform screen scale will be set to "+80ºC to -20ºC".
When this setting has been changed, the waveform screen scale will be set to "+80ºC to -20ºC".
When this setting has been changed, the waveform screen scale will be set to "+80ºC to -20ºC".
3.How to make a Trace setting.
The Trace parameter can be used to specify the selected waveform to be visible or invisible on
the display.
 (1) Press the SPAN/POSITION/TRACE key to select the TRACE mode.
 (2) Use the
and
keys to make CH 1 active (enlarged display).
 (3) Use the
and
keys to select Off.
  When this setting has been changed, the CH 1 waveform is not displayed.
  When this setting has been changed, the CH 1 waveform is not displayed.
The currently selected mode
(SPAN, POSITION or TRACE)
can be checked by looking at
the "Waveform Operation Display Area".
keys to make CH 1 active (enlarged display).
keys to make CH 1 active (enlarged display).
keys to make CH 1 active (enlarged display).
keys to change the Span value. Here the value for span is set to 100ºC.
17