Leica 3D Disto User Manual page 125

Hide thumbs Also See for 3D Disto:
Table of Contents

Advertisement

3D Disto, Software Applications
Location Check
step-by-step
If the 3D Disto was unintentionally moved, for example got bumped, the geometry
of the measured points will no longer fit with that of the previously measured points.
Start a Location Check to sustain the current accuracy/geometry.
1. To initiate a Location Check press Menu » Applications » Location » Location
Check.
If there are no Secure Points in the memory, no Location Check is
possible.
2. If Secure Points are available, select Secure Point and press
will target the Secure Point automatically. Check laser point position with target
mark. Proceed that way for checking further points.
If laser point does not target the centre of the target mark, Relocation
is recommended.
3. Press
to close Secure Point gallery.
All Location applications can be cancelled by pressing
125
. The 3D Disto
.

Advertisement