Falcon 2800 Plus Automatic Carpet Extractor Model No.: Operator and Parts Manual 608352 609260 NOBLES 12875 RANSOM STREET HOLLAND MI 49424 U.S.A. 607210 CUSTOMER SERVICE: 1-800-365-6625 OUTSIDE U.S.: 1–616–786–2330 Rev. 00 (02-00) FAX: 1–800–678–4240 Home Find... Go To..
Distributor. E2000 Tennant Company Printed in U.S.A Nobles is a registered United States trademark of Tennant Company. This machine will provide excellent service. However, Specifications and parts are subject to change without notice. the best results will be obtained at minimum costs if: The machine is operated with reasonable care.
OPERATION – Follow mixing and handling instructions on chemical containers. SAFETY PRECAUTIONS 4. Before leaving or servicing machine: – Stop on level surface. This machine is intended for commercial use. It is – Turn off machine. suited to clean carpet and upholstery in an indoor –...
OPERATION FILLING SOLUTION TANK SETUP AND OPERATION Open fill port door at front of machine and fill with 106 liters (28 gal) of hot water, 60_C (140_F) maximum, and add liquid cleaning solution to proper dilution ratio MACHINE INSTALLATION (Figure 3). ATTENTION: To prevent damage to machine when FOR SAFETY: When using machine, follow mixing uncrating, do not attempt to drive or roll off skid.
OPERATION CONNECTING MACHINE TO POWER SOURCE CLEANING CARPET 1. Connect equipped extension cord to short pigtail FOR SAFETY: Do not operate machine unless cord on machine (For 220V models plug directly operator manual is read and understood. into wall outlet). 1.
OPERATION 6. To begin cleaning, rotate control grips forward and adjust speed control knob according to specific OPERATING PRESPRAY WAND cleaning mode (Figure 9): While cleaning, prespray traffic areas and spots using RESTORATIVE CLEANING: built–in prespray wand. To activate wand, turn on main 15 M (50 ft.) per minute.
OPERATION CIRCUIT BREAKERS The machine is equipped with two circuit breakers located on control housing at rear of machine. 1. Brush motor is protected by a 1.5 amp circuit breaker. If breaker should trip, adjust brush height or remove any obstruction in brush. Reset breaker button.
OPERATION 2. Remove recovery tank dome and rinse out tank. You can use the spray wand to rinse out recovery MACHINE MAINTENANCE tank. Be careful not to spray water into standpipe screen (Figure 16). To keep machine in good working condition, simply follow machine’s daily, weekly and monthly maintenance procedures.
OPERATION d. Allow solution to remain in system overnight in above freezing temperatures. ADJUSTING DRIVE BELT e. Next day, drain solution tank and run 13L (3 FOR SAFETY: When servicing machine, unplug gal) of clean water through system to flush out cord from wall outlet.
OPERATION TROUBLE SHOOTING PROBLEM CAUSE SOLUTION Machine does not operate Faulty main switch or wiring Contact Service Center Faulty power cord Contact Service Center Building circuit breaker tripped Reset breaker and plug machine into a circuit which is not heavily loaded Brush motor does not operate 1.5 amp brush circuit breaker tripped There are several reasons why this...
Page 11
OPERATION TROUBLE SHOOTING –continued PROBLEM CAUSE SOLUTION No spray through spray tips Main power switch is not turned on Turn on main power switch Pump switch is not turned on Turn on pump switch Control grips not rotated Rotate control grips forward to start pump, brush and drive motors Bowl filter screen plugged See Weekly Maintenance...
PARTS LIST SOLUTION TANK/RECOVERY TANK GROUP 43 42 Falcont2800 Plus (09–99) Home Find... Go To..
Page 13
HOSE, EXHAUST 2” 36” ASSEMBLY 608840 CHASSIS GREEN INCLUDED IN ASSEMBLY DECAL LIST (NOT SHOWN) PART # DESCRIPTION QTY. 608469 DECAL, FALCON 2800 PLUS 120399 DECAL, DO NOT ALLOW FOAM 608185 DECAL, NOBLES LOGO Falcont2800 Plus (09–99) Home Find... Go To..
ELECTRICAL DIAGRAMS WIRE DIAGRAM 120 V POWER CORD MAIN PUMP SWITCH SWITCH POTENTIOMETER 230 V 5 kW POWER CORD BRUSH HEIGHT METER WHT/ORG WHT/ORG AC AC A+ HI W LO SPEED CONTROL BOARD CONDUIT TO CHASSIS 2.5 AMP 1.5 AMP CIRCUIT CIRCUIT INTERIM/RESTOR...
Page 27
ELECTRICAL DIAGRAMS LADDER DIAGRAM LINE 1 LINE 2 MAIN SWITCH VACUUM POTENTIOMETER SWITCH 5 KW VACUUM MOTOR SPEED CONTROL BOARD TERMINALS AC AC A+ A/F W LO ROLL SWITCH 1 CIRCUIT BREAKER 2.5 AMP DRIVE MOTOR ROLL SWITCH 2 CIRCUIT BREAKER 1.5 AMP PUMP...
Need help?