Intake Leak Test - Buell 2005 FIREBOLT Service Manual

Table of Contents

Advertisement

HOME

INTAKE LEAK TEST

GENERAL
1
DANGER
Be sure to follow manufacturer's instructions when
using the UltraTorch UT-100 or any other radiant heating
device. Failure to follow manufacturer's instructions can
cause a fire, which could result in death or serious injury.
(00335a)
Avoid directing heat toward any fuel system component.
Extreme heat can cause fuel ignition/explosion resulting
in death or serious injury.
Avoid directing heat toward any electrical system compo-
nent other than the connectors on which heat shrink
work is being performed.
Always keep hands away from tool tip area and heat
shrink attachment.
To prevent false readings, keep airbox cover installed
when performing test.
Do not direct propane into air scoop, false readings will
result.
LEAK TESTER
Parts List
Standard 14oz. propane cylinder.
HD-41417 Propane Enrichment Kit.
12 in. (304 mm) long-1/4 in. (6mm) diameter copper tub-
ing.
Tester Assembly
1.
Cut rubber hose from kit to 18 in. (457 mm) in length.
2.
See
Figure 4-116.
Flatten one end of copper tube to form
a nozzle.
3.
Insert round side of copper tube into end of tubing.
4-128 2005 Buell Firebolt: Fuel System
9648
Figure 4-116. Nozzle
9649
1
3
2
1.
Nozzle
2.
Copper tube
3.
Hose
4.
Valve
5.
Knob
6.
Propane bottle
Figure 4-117. Leak Tester
4.44
4
5
6

Advertisement