Cooking timer LEDs:
-
Each zone has a LED, which is signalising if a cooking time is set.
-
This LED blinks if the setting of the cooking time for this zone is enabled (time selection
enabled).
-
This LED is continuously ON if a cooking time is set.
-
If timer selection is deactivated the LED for the zone with the lowest cooking time must blink
with a slower frequency.
Timer display:
-
If timer setting is enabled the timer display shows the according time which can be changed.
-
If timer setting is disabled the timer display shows nothing if no time is set.
-
If timer setting is disabled the timer display shows the lowest cooking time if set.
Timer end:
-
The buzzer rings in a pleasant sound and the LED is blinking for max. two minutes.
-
If a cooking time has elapsed the according zone must be switched off.
-
The signalisation of a timer end can be stopped by pressing one of the timer buttons.
-
The cooking end procedure starts again with each new ending of a cooking timer.

4.7.2 One key timer

The „+" and „-" keys of a zone are used for the time setting if the timer is activated with the timer
select key. So only 1 timer key (timer select key) is used, in some documentation this was also
called "Centronica" timer. This kind of timer is used for large hobs, Centronica and induction hobs.
The „+" key of the timer is used as Key Lock. The „-" key of the timer is optional used as Stop&Go
(only HIC horizontal for induction).
Details of Timer function:
-
With the timer select key the timer is activated. Like in standard 3 key timer the first active
zone (order: front left – back left, back right, front right) is selected if no timer is activated. Af-
ter selection of one zone for the timer (toggle to the zone with timer select key) you set with
the + / - keys of the activated zone the time.
4.8

Pot Detection / Empty pot

-
If no pot is detected and the power level is set to a level > „0", a „F" is blinking.
The induction power board switches the zone off after 10 min. if no pot is detected.
-
Over temperature of pot or dry boiling pot (coil temperature sensor).
If the power has to be switched off, the power board sends a Hob Power management- actual
status message (FB
before a new value can be set.
DGN-TDS-N 11.03 U. H. / A. B. © Electrolux
). In the display a „-" is shown. The user has to switch off the zone,
h
- 16 -
599 512 232
EN