To check the first intake of air
a Retaining screw
b Air valve
Gap X must measure:
For natural gas:
For liquid gas:
Conversion to another type of gas
13 mm
13 mm
If it doesn't:
^ Loosen the retaining screw, move the
air valve, and tighten the retaining
screw again.
^ Finally secure the jets against
inadvertent loosening with sealing
wax.
^ Re-assemble the cooktop in the
reverse order.
The flame must not go out on the lowest
setting, or when the control is turned
quickly from a high to a low setting.
On the highest setting the flame must
have a distinctive and visible core.