Control panel message
1796-SATA Cabling Error
2212-USB Key Provisioning failure writing to
device
2217-ME Firmware Version request failure
2218-ME Firmware Version should be updated
2219-USB Key Provisioning file has invalid
header identifier
2220-USB Key Provisioning file has mismatch
version
Invalid Electronic Serial Number
Network Server Mode Active and No Keyboard
Attached
108 Chapter 8 POST error messages
Description
One or more SATA devices are improperly
attached. For optimal performance, the SATA 0
and SATA 1 connectors must be used before
SATA 2 and SATA 3.
USB device used for USB key provisioning will
not allow BIOS to update provision file
properly.
ME firmware is not properly responding to BIOS
query for version information.
ME firmware must be updated to match current
functionality contained in the system BIOS.
Provisioning file contained on the USB key has
been corrupted or is not a valid version for the
current ME firmware.
Provisioning file contained on the USB key is
not a valid version for the current ME firmware.
Electronic serial number is missing.
Keyboard failure while Network Server Mode
enabled.
Recommended action
2.
Apply hard drive firmware patch
if applicable. (Available at
http://www.hp.com/support.)
3.
Back up contents and replace hard drive.
Ensure SATA connectors are used in ascending
order. For one device, use SATA 0. For two
devices, use SATA 0 and SATA 1. For three
devices, use SATA 0, SATA 1, and SATA 2.
1.
Try a different USB key device for
provisioning.
2.
If the error persists, update to the latest
BIOS version and ME firmware version.
3.
If the error still persists, replace the
system board.
1.
Reboot the computer.
2.
If the error persists, update to the latest
BIOS version and ME firmware version.
3.
If the error still persists, replace the
system board.
1.
Update to the latest ME firmware version.
2.
If the error persists and system BIOS has
been recently updated, restore previous
system BIOS version.
3.
If the error still persists, replace the
system board.
1.
Recreate the provisioning file using third
party management console software.
2.
If the error persists and system BIOS has
been recently updated, restore previous
system BIOS version. Otherwise, update
the ME firmware version.
3.
If the error still persists, replace the
system board.
1.
Reboot the computer.
2.
If the error persists and system BIOS has
been recently updated, restore previous
system BIOS version. Otherwise, update
the ME firmware version.
3.
If the error still persists, replace the
system board.
Enter the correct serial number in Computer
Setup.
1.
Reconnect keyboard with computer
turned off.
2.
Check connector for bent or missing pins.
3.
Ensure that none of the keys are
depressed.

Hide quick links: